Priming - H.C Duke & Son Electro Freeze COMPACT Series Operator's Manual

Soft serve freezer
Table of Contents

Advertisement

ELECTRO FREEZE Model CS600
9.1
Sanitizing -
sanitizing solution, reconnect the main
power supply to the freezer. Place the
selector switch to the "CLEAN" position
(figure 9-1). Allow the beater to run for 5
minutes. During this time period also check
for leaks around the head, plunger and drain
tube.
Do not use the "AUTO" position with
sanitizer in the cylinder. The freezer will
be damaged.
9.2

Priming

Pin is in line with hole.
Look through top hole
in tube — you should
see clear through.
Figure 8-2
Priming the freezer removes all excess air
and sanitizer from the freezing cylinder and
sets the proper overrun for the first cylinder
of product. Always have clean, sanitized
hands when handling mix feed assemblies.
Handle only the top 1" (2,5cm).
forearms.
dispense head. Install the mix feed tube
assembly in the "closed" position into the
mix feed drain in the hopper. Pour a mini-
mum of 2-1/2 gallons (9,5 liters) of mix into
the hopper. Hold plunger open and remove
mix feed tube and allow mix to push out the
16
continued
6. When the cylinder has filled with
Important:
Pin is not in line with hole.
Look through top hole
in tube — you should
see the inner white
plastic insert tube
blocking the opening.
Mix Feed Tube Positions
1. Wash and sanitize your hands and
2. Place an empty container under the
7. Place an empty container under
the dispensing head and drain the solution
by opening the plunger to allow the
cylinder and hopper to empty. Open and
close the plunger at least 10 times during
draining to sanitize the port area of the
dispense head.
8. When the sanitizing solution has
drained from the freezer, turn the selector
switch to the "OFF" position.
sanitizer. When pure mix flows from the
dispense head close the plunger. Install the
mix feed tube into the mix feed hopper
drain in the "open" position as shown in
figure 8-2 and place the selector switch to
the "Auto" position.
Important:
Failure to completely remove
sanitizer or water from the freezing
cylinder before placing in "AUTO"
will damage the freezer.
3. Install the hopper cover.
4. During long idle periods, the white
plastic insert tube should be closed — but
remember — when dispensing product,
ensure that the mix feed insert is OPEN
at all times. If not open, the flow of mix will
be restricted. If lubricant blocks the inlet
hole in the tube it would also restrict the
flow of mix.
184596