MTS Troubleshooting Tables
PROBLEM
PROBABLE CAUSE
Mix leaks out of
1. Transfer hose worn or split.
MTS.
1. Pump cover not installed.
2. Hose not installed properly.
3. Slide switch defective.
Mix transfer
4. MTS relay defective.
system (MTS)
will not operate.
5.
6. Pressure switch defective.
7.
1. Hose broken.
MTS will not
shut off.
2. Pressure switch stuck in closed position.
1. Worn transfer hose.
MTS cycles on
and off without
dispensing.
2. Leak on pressure side of system.
1. Insufficient supply of mix.
2. Swing clamp knob loose.
MTS will not
prime.
3. Air hose or air meter not installed.
4. Hose not installed.
1. Defective or missing duckbill valve.
Mix pickup tube
2. Inlet clamp not tight.
loses prime.
3. Worn transfer hose.
185240
Start capacitor defective or motor start
switch defective.
Motor defective or internal overload
tripped.
REMEDY
Remove cover, clean inside MTS
around rollers with spray bottle
1.
provided. Install new hose. Do not
twist hose.
1. Install cover.
2. Check position – reinstall.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
Contact your Electro Freeze
5.
Distributor for service.
Contact your Electro Freeze
6.
Distributor for service.
Contact your Electro Freeze
7.
Distributor for service.
1. Replace hose.
Contact your Electro Freeze
2.
Distributor for service.
1. Replace hose.
Contact your Electro Freeze
2.
Distributor for service.
1. Replenish mix supply.
2. Tighten knob.
3. Install air hose/air meter.
4. Install hose.
1. Replace duckbill valve.
2. Tighten clamp.
3. Replace transfer hose.