ELECTRO FREEZE Soft Serve Model GEN-2080
17 Troubleshooting Tables
PROBLEM
PROBABLE CAUSE
Discharge
1.
pressure too high.
2.
3.
4. Dirty air condenser. (air cooled models)
5.
6. Refrigerant overcharge.
7. Air in system.
Discharge
1.
pressure too low.
2. Shortage of refrigerant.
Noisy
1. Tubing rattles.
compressor.
2. Spring broken internally.
NOTE: Contact your authorized Electro Freeze Distributor for instructions
prior to warranty compressor replacement.
72
Water hose kinked or pinched. (water
cooled models)
Water turned off or defective water
regulating valve. (water cooled models)
Restricted water cooled condenser.
(water cooled models)
Unit location too warm (air cooled
models)
Water regulating valve open too wide.
(water cooled model)
(continued)
REMEDY
Move freezer and adjust hose so it is
1.
not pinched or kinked.
Turn on water, or contact your Electro
2.
Freeze Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
Contact your Electro Freeze
5.
Distributor for service.
Contact your Electro Freeze
6.
Distributor for service.
Contact your Electro Freeze
7.
Distributor for service.
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
1.
Distributor for service.
Contact your Electro Freeze
2.
Distributor for service.
185240