ELECTRO FREEZE Soft Serve Model GEN-2080
17 Troubleshooting Tables
PROBLEM
PROBABLE CAUSE
1. Improperly wired.
2. Low line voltage.
Compressor will
not start – hums
intermittently
3. Open start capacitor. (Single phase only)
(cycling on
overload)
4. High discharge pressure.
5. Defective compressor
Compressor
starts, but remain
1. Low line voltage.
in start windings.
2. Improperly wired.
3.
4.
185240
Running capacitor shorted. (Single phase
only).
Start capacitor weak. (Single phase
only).
(continued)
REMEDY
Contact your Electro Freeze
1.
Distributor for service.
Ask power company to increase
voltage to not less than 10% below
2.
dataplate rating or have transformer
installed. Have wire checked for
inadequate wire size.
Contact your Electro Freeze
3.
Distributor for service.
See "Discharge pressure too high"
4.
this section.
Contact your Electro Freeze
5.
Distributor for service.
Ask power company to increase
voltage to not less than 10%
1.
below nameplate rating or install
transformer.
Contact your Electro Freeze
2.
Distributor for service.
Contact your Electro Freeze
3.
Distributor for service.
Contact your Electro Freeze
4.
Distributor for service.
71