Connectable devices
The following table contains the components that can communicate with SIMOTION D410
via the DRIVE-CLiQ interface. Note the max. number of nodes that can be connected to the
DRIVE-CLiQ!
Table 3-7
DRIVE-CLiQ connection topology
Components
Drive
Encoder via Sensor Module Cabinet (SMC)
and Sensor Module Integrated (SMI)
Terminal expansion modules
DRIVE-CLiQ hub module 20 (DMC20)
The following figures show 2 example topologies of components that can be connected to
the DRIVE-CLiQ.
Figure 3-2
D410
Manual, 03/2007 Edition
Max. number of connectable nodes
Max. 1 drive from the following:
Blocksize power module (PM340), only possible for operation away from
•
the power module with CUA31 (see chapter "Installation")
Power Module Chassis AC/AC
•
Max. 2 of the following encoder modules:
SMC10
•
SMC20
•
SMC30
•
Encoder connection via motor with DRIVE-CLiQ interface (SMI)
•
Max. 3 of the following terminal modules:
TM15 terminal module
•
High feature terminal module TM17
•
TM31 terminal module
•
TM41 terminal module
•
Max. 1 DMC20
Note: Because an SMC and an SMI only have one DRIVE-CLiQ interface, a
DMC20 must be used for a second encoder on DRIVE-CLiQ. If a CUA31 is
used, then the DMC20 is not required.
Example topology: 3 terminal modules, 1 encoder via SMI, 1 encoder via SMC
Interfaces
3.3 DRIVE -CLiQ interface
33