Digital inputs
4 digital inputs are available on the control unit.
The electrically isolated inputs can be used as user-addressable inputs.
Switches or proximity encoders (2- or 3-wire encoders) can be connected.
The inputs comply with the standard IEC 1131-2/DIN EN 61131-2, characteristic type 2
(24 V P switching).
Bidirectional digital inputs/outputs
4 digital inputs/outputs (DI/DO) are available on the SIMOTION D410.
The following application options are available when configuring the DI/DO as digital inputs:
• DI/DO9, 10 and 11 can be used as "fast inputs" for measuring inputs.
• All 4 DI/DO can be used as user-addressable inputs or as homing inputs.
The following application options are available when configuring the DI/DO as digital outputs:
• Use as onboard outputs
• Use as "fast output cams"
The outputs comply with the standard IEC 1131-2/DIN EN 61131-2 (24 V P switching).
Additional references
For information on configuring the I/O addresses and on using the "fast inputs" as measuring
inputs, see the Commissioning Manual,
For further information on configuring the digital inputs as measuring inputs and the digital
outputs as fast output cams, see the Function Manual,
Measuring Inputs
D410
Manual, 03/2007 Edition
The inputs can be arranged in any way; the special application is activated in the
SIMOTION SCOUT Engineering System when configuring the TO measuring inputs via
the HW address and the bit number.
, /8/.
SIMOTION D410
, /1/.
SIMOTION Output Cams and
Interfaces
3.2 Digital inputs/outputs