Proceed as follows to connect the USB-CAN interface with the PC and your unit:
1. Connect the 9-pin D-sub connector of the USB-CAN interface with the prefabricated
2. Connect the second cable end (without terminating resistor) with the SBus interface
Signal
CAN_H
CAN_L
CAN_GND
3. If the unit is operated within a CAN network, connect the terminating resistor at the
4. Plug the USB-A connector of the USB cable into a free USB interface on your PC [1].
For detailed information about the startup of a USB-CAN interface in connection with a
MOVIAXIS
structions.
9.8.3
Configuring the communication via SBus
You need an SBus connection between your PC and the units you want to configure.
You can use a USB-CAN interface for this purpose.
Proceed as follows to configure SBus communication:
1. Click on "Configure communication plugs" [1] in the toolbar.
Manual – DFE32B Fieldbus Interface PROFINET IO
MOVITOOLS® MotionStudio – Operation
Communication SBus (CAN) via interface adapter
connection cable. Make sure that the cable end with the terminating resistor leads to
the USB-CAN interface.
[3] of the unit [4].
®
•
If MOVIDRIVE
is equipped with the DFC11B connection option, you can con-
nect the D-sub plug of the prefabricated cable directly with terminal X30.
•
Without the connection option, connect the cores of the prefabricated cable to the
X12 terminal of MOVIDRIVE
Terminal on
MOVIDRIVE
X12:2
X12:3
X12:1
last unit.
®
unit, refer to the "MOVIAXIS
[1]
"Configure communication plugs" symbol
®
as follows:
CAN pin assignment
®
(9-pin D-sub connector)
PIN 7
PIN 2
PIN 3
®
MX Multi-Axis Servo Inverter" operating in-
9
Core
(Deviations are pos-
sible)
Brown
White
Shielding
[1]
68062AXX
109
Need help?
Do you have a question about the DFE32B PROFINET IO and is the answer not in the manual?
Questions and answers
Bus fault
Common causes of a bus fault in SEW-Eurodrive DFE32B PROFINET IO include:
1. No connection between the inverter and Ethernet.
2. PROFINET IO controller is switched off or not started.
3. Mismatch between the PROFINET device name in the project and the inverter.
4. Incorrect or missing configuration of the DFE32B option (wrong device name or IP address).
5. Faulty or incorrect bus cabling.
6. Incorrect unit type or configuration used in project planning.
This answer is automatically generated