Danfoss VLT Brook Crompton Motor FCM 300 Design Manual page 93

Table of Contents

Advertisement

All about FCM 300
Parameter
No.
Function
200
Rotation direction
201
Min. output frequency
(f
)
MIN
202
Max. output frequency
(f
)
MAX
203
Reference/feedback
range
204
Minimum reference
205
Maximum reference
207
Ramp-up time 1
208
Ramp-down time 1
209
Ramp-up time 2
210
Ramp-down time 2
211
Jog ramp time
212
Quick stop ramp-down
time
213
Jog frequency
214
Reference function
215
Preset reference 1
216
Preset reference 2
219
Catch up/slow down
value
221
Current limit for motor
mode
229
Frequency bypass,
bandwidth
230
Frequency bypass 1
231
Frequency bypass 2
241
Reference preset 1
242
Reference preset 2
243
Reference preset 3
244
Reference preset 4
245
Reference preset 5
246
Reference preset 6
247
Reference preset 7
Table 4.13 Functions to Programme, to Control and to Monitor via Bus (PROFIBUS) or by PC.
Parameter
No.
Function
317
Time out
318
Function after time out
323
X102 relay function
327
Pulse reference/feedback, max. freq.
331
Terminal 1, analog input current
332
Terminal 2, digital input
333
Terminal 3, digital input
334
Terminal 4, digital input
335
Terminal 5, digital input
336
Terminal 1, min. scaling
337
Terminal 1, max. scaling
338
Terminal 2, min. scaling
339
Terminal 2, max. scaling
340
Output functions
Table 4.14 Functions to Programme, to Control and to Monitor via Bus (PROFIBUS) or by PC.
®
VLT
DriveMotor FCM Series
Range/number of settings/value
3
0.0 Hz-f
MAX
f
-f
MIN
RANGE
Min. - max./-max.- +max.
-100,000.000-Ref
MAX
Ref
-100,000.000
MIN
0.05-3600.00 s
0.05-3600.00 s
0.15-3600.00 s
0.15-3600.00 s
0.05-3600.00 s
0.05-3600.00 s
0 Hz - f
MAX
2
-100.00%-+100.00%
-100.00%-+100.00%
0.00-100.00%
Min.- max. limit in% of I
rated
0 (off)-100%
0.0-132 Hz
0.0-132 Hz
-100.00%-+100.00%
-100.00%-+100.00%
-100.00%-+100.00%
-100.00%-+100.00%
-100.00%-+100.00%
-100.00%-+100.00%
-100.00%-+100.00%
Range/number of settings/value
1-99 s
Off/Stop and trip
14
100-70000 Hz
3
31
31
30
29
0.0-20.0 mA
0.0-20.0 mA
0.0-10.0 V
0.0-10.0 V
24
®
MG03BA02 - VLT
is a registered Danfoss trademark
Factory setting
Only clockwise 0-132 Hz
0.0 Hz
f
(132 Hz)
RANGE
Min. - Max.
0.000
50.000
3.00 s
3.00 s
3.00
3.00 s
3.00 s
3.00 s
10.0 Hz
Sum
0.00%
0.00%
0.00%
Max. limit
0%
0.0 Hz
0.0 Hz
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
Data
Factory setting
type
10 s
5
Off
5
No operation
5
5000 Hz
7
No operation
6
Reference
6
Reset
6
Start
6
Jog
6
0.0 mA
6
20.0 mA
6
0.0 V
6
10.0 V
6
No operation
6
Conv
Data
.
type
index
5
0
6
-1
6
-1
5
0
4
4
4
-3
4
-3
7
-2
7
-2
7
-2
7
-2
7
-2
7
-2
6
-1
5
0
3
-2
3
-2
6
-2
6
-1
6
0
6
-1
6
-1
3
-2
3
-2
3
-2
3
-2
3
-2
3
-2
3
-2
Conv.
index
0
0
0
0
0
0
0
0
0
-4
-4
-1
-1
0
91

Advertisement

Table of Contents
loading