Programming
[2] Control card test is selected if control of the analogue
and digital inputs, as well as the analogue, digital outputs
and the +10 V control voltage is desired.
A test connector with internal connections is required for
this test. Setup: Analogue/digital output to digital inputs 3,
3
3
4 and 5 and 10 V supply to analogue/digital input 2.
[3] Initialization is selected if the factory setting of the unit
is desired without resetting parameters 500, 501 + 600 -
605. Initialisations active after power up.
621
Nameplate: FC type
Value:
Depends on unit
Function:
The key data of the unit can be read out via the display or
the serial communication.
Description of choice:
Type indicates the unit size and basic function concerned.
624
Nameplate: Software version no.
Value:
Depends on unit
Function:
The key data of the unit can be read out via the display or
the serial communication.
Description of choice:
Software version gives the version number.
625
Nameplate: LCP identification no.
Value:
Depends on unit
Function:
The key data of the unit can be read out via the display or
the serial communication port. For example: ID 1,42 2 kB.
626
Nameplate: Database identification no.
Value:
Depends on unit
Function:
The key data of the unit can be read out via the display or
the serial communication port.
628
Nameplate: Application option type
Value:
Function:
The key data of the unit can be read out via the display or
the serial communication port.
Nameplate: Communication option type
630
ordering no.
Value:
76
®
VLT
DriveMotor FCM Series
Function:
The key data of the unit can be read out via the display or
the serial communication port.
632
Value:
Function:
The key data of the unit can be read out via the display or
the serial communication port.
633
Value:
Function:
The key data of the unit can be read out via the display or
the serial communication port.
634
Value:
Function:
The key data of the unit can be read out via the display or
the serial communication port.
635
Value:
Function:
The key data of the unit can be read out via the display or
the serial communication port.
678
Value:
Standard version (STANDARD VERSION)
Profibus 3 Mbaud Version
(PROFIBUS 3 MB VER.)
Profibus 12 Mbaud Version
(PROFIBUS 12 MB VER.)
Function:
This parameter enables a configuration of a Profibus
Control Card. The default value depends on the produced
unit, also being the maximum obtainable value. This
means, that a control card only can be down graded to a
lower performance version.
®
MG03BA02 - VLT
is a registered Danfoss trademark
BMC software identification
Motor database identification
Unit identification for communication
Software Part No.
Configure Control Card