Danfoss VLT Brook Crompton Motor FCM 300 Design Manual page 51

Table of Contents

Advertisement

Programming
Parameter
Digital input on terminal no.
Settings
No function
Reset
Coasting stop, inverse
Reset and coasting stop, inverse
Quick-stop, inverse
DC-braking, inverse
Stop inverse
Start
Latched start
Reversing
Start reversing
Start clockwise, on
Start counter-clockwise, on
Jog
Freeze reference
Freeze output
Speed up
Speed down
Selection of Setup
Catch-up
Slow-down
Preset reference
Preset reference, on
Precise stop, inverse
Pulse reference
Pulse feedback
Analogue reference
Analogue feedback
Reset and start
Freeze reference and start
Ramp 2
Start-ref bit 1
Start-ref bit 2
Start-ref bit 3
Table 3.11
Function:
In parameters 332-335 it is possible to choose between the
different possible functions related to the inputs on
terminals 2-5. The function options are shown in
Table 3.13.
Description of choice:
No function is selected if the FC motor is not to react to
signals transmitted to the terminal.
Reset zeroes the FC motor after an alarm; however, not all
alarms can be reset without disconnecting from mains.
Coasting stop, inverse is used for making the FC motor run
freely to stop. Logic '0' leads to coasting stop.
Reset and coasting stop, inverse, is used for activating
coasting stop at the same time as reset.
®
VLT
DriveMotor FCM Series
(NO OPERATION)
(RESET)
(MOTOR COAST INVERSE)
(RESET & COAST INV.)
(QUICK STOP INVERSE)
(DC-BRAKE INVERSE)
(STOP INVERSE)
(START)
(LATCHED START)
(REVERSING)
(START REVERSING)
(ENABLE FORWARD)
(ENABLE REVERSE)
(JOGGING)
(FREEZE REFERENCE)
(FREEZE OUTPUT)
(SPEED UP)
(SPEED DOWN)
(SETUP SELECT)
(CATCH UP)
(SLOW DOWN)
(PRESET REF.)
(PRESET REF. ON)
(PRECISE STOP)
(PULSE REFERENCE)
(PULSE FEEDBACK)
(REFERENCE)
(FEEDBACK)
(RESET AND START)
(FREEZE REF AND START)
(RAMP 2)
(START-REF BIT 1)
(START-REF BIT 2)
(START-REF BIT 3)
Logic '0' leads to coasting stop and reset.
Quick stop, inverse is used for stopping the motor in
accordance with the quick-stop ramp (set in parameter
212).
Logic '0' leads to a quick-stop.
DC breaking, inverse is used for stopping the motor by
energizing it with a DC voltage for a given time, see
parameters 126-132.
Note that this function is only active if the settings of
parameters 126-132 is different from 0. Logic '0' leads to
DC braking.
Stop inverse is activated by interrupting the voltage to the
terminal. This means that if the terminal has no voltage,
®
MG03BA02 - VLT
is a registered Danfoss trademark
332
333
334
2
3
4
[0]
[0]
[0]
[1]
[1]
[1]
[2]
[2]
[2]
[3]
[3]
[3]
[4]
[4]
[4]
[5]
[5]
[5]
[6]
[6]
[6]
[7]
[7]
[7]
[8]
[8]
[8]
[9]
[9]
[9]
[10]
[10]
[10]
[11]
[11]
[11]
[12]
[12]
[12]
[13]
[13]
[13]
[14]
[14]
[14]
[15]
[15]
[15]
[16]
[16]
[16]
[17]
[17]
[17]
[18]
[18]
[18]
[19]
[19]
[19]
[20]
[20]
[20]
[21]
[21]
[21]
[22]
[22]
[22]
[23]
[24]
[25]
[30]
[31]
[32]
[32]
[32]
[33]
[33]
[33]
[34]
[34]
[34]
[35]
[35]
[35]
[36]
[36]
[36]
[37]
[37]
[37]
335
5
[0]
[1]
3
3
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[32]
[33]
[34]
[35]
[36]
[37]
49