Programming
Description of choice:
The jog frequency f
can be selected in the range
JOG
between f
(parameter 201) and f
MIN
512
Telegram profile
Value:
Fieldbus Profile (FIELDBUS PROFILE)
FC Profile (FC PROFILE)
Function:
There is a choice of two different control word profiles.
Description of choice:
Select the desired control word profile.
See Serial communication for further information about the
control word profiles.
513
Bus time interval
Value:
1-99 s
1 s
Function:
This parameter sets the maximum time expected to pass
between the receipt of two consecutive telegrams. If this
time is exceeded, the serial communication is assumed to
have stopped and the desired reaction is set in parameter
514.
Description of choice:
Set the desired time.
514
Bus time interval function
Value:
Off (OFF)
Freeze output (FREEZE OUTPUT)
Stop (STOP)
Jogging (JOGGING)
Max. speed (MAX SPEED)
Stop and trip (STOP AND TRIP)
Function:
This parameter selects the desired reaction of the FC
motor when the set time for bus timeout (parameter 513)
has been exceeded. If choices [1] to [5] are activated, relay
01 and relay 04 will be de-activated.
Description of choice:
The output frequency of the FC motor can: be frozen at
the present value, be frozen at the reference, go to stop,
go to jogging frequency (parameter 213), go to max.
output frequency (parameter 202) or stop and activate a
trip.
515
Data read-out: Reference %
Value:
XXX.X%
Function:
This parameter can be read out via the serial communi-
cation port.
®
VLT
DriveMotor FCM Series
(parameter 202).
MAX
[0]
[1]
[1-99]
[1]
[0]
[1]
[2]
[3]
[4]
[5]
[XXXX]
®
MG03BA02 - VLT
is a registered Danfoss trademark
Description of choice:
The value shown corresponds to the total reference (sum
of digital/analogue/preset/bus/freeze ref./catchup and
slow-down).
This value is updated every 320 ms.
516
Data read-out: Reference unit
Value:
X.XXX Hz or rpm.
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
Indicates the status value of the unit given on the basis of
the choice of the reference sum.
This value is updated every 320 ms.
517
Data read-out: Feedback
Value:
X.XXX
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
Indicates the status value of terminals 1/2 at the unit/scale
selected in parameters 414 and 415.
This value is updated every 320 ms.
518
Data read-out: Frequency
Value:
XXX.X Hz
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value shown corresponds to the actual motor
frequency.
This value is updated every 320 ms.
519
Data read-out: Frequency x scale
Value:
XXX.X Hz
Function:
This parameter can be read out via the serial communi-
cation port.
Description of choice:
The value corresponds to the present output frequency f
multiplied by the factor preset in parameter 008 Display
scaling of output frequency.
520
Data read-out: Current
Value:
XXX.XX A
3
3
[XXXX]
[XXXX]
[XXXX]
[XXXX]
M
[XXXXX]
71