Programming
Operating variable:
Reference
Reference
Feedback
Frequency
Frequency x scaling
Motor current
Torque
Power
Power
Motor voltage
DC-link voltage
FC thermal
Hours run
Input status, dig. Input
External reference
Status word
Heat sink temp.
Alarm word
Control word
Warning word 1
Warning word 2
Analog input 1
Analog input 2
*) Select in parameter 416. The unit is shown in readout state 1
line 1 otherwise 'U' is shown.
Table 3.5
Operating variables 1.1 and 1.2 and 1.3 in the first line, and
operating variable 2 in the second line are selected via
parameter 009, 010, 011 and 012.
Read-out state I:This read-out state is standard after
starting up or after initialisation.
FREQUENCY
50.0 Hz
MOTOR IS RUNNING
Line 2 gives the data value of an operating variable with
related unit, and line 1 provides a text which explains line
2, cf. table. In the example, Frequency has been selected
as variable via parameter 009. During normal operation
another variable can immediately be read out by using the
[+]/[-] keys.
Read-out state II:
®
VLT
DriveMotor FCM Series
Unit
[%]
[unit]*
[unit]*
[Hz]
[-]
[A]
[%]
[kW]
[HP]
[V]
[V]
[%]
[Hours]
[Binary code]
[%]
[Hex]
[ºC]
[Hex]
[Hex]
[Hex]
[Hex]
[mA]
[V]
®
MG03BA02 - VLT
is a registered Danfoss trademark
Switching between read-out states I and II is effected by
pressing the [DISPLAY/STATUS] key.
24.3% 30.2% 13.8A
50.0 Hz
MOTOR IS RUNNING
In this state, data values for four operating values are
shown at the same time, giving the related unit, cf. table.
In the example, Reference, Torque, Current and Frequency
are selected as variables in the first and second line.
Read-out state III:
This read-out state can be held as long as the [DISPLAY/
STATUS] key is pressed. When the key is released, the
system switches back to Read-out state II, unless the key is
pressed for less than approx. 1 s.
REF% TORQUE CURR A
50.0 Hz
MOTOR IS RUNNING
This is where parameter names and units for operating
variables in the first line are given - operating variable 2
remains unchanged.
3.1.11 Quick Menu Mode Versus Menu
Mode
The FC motor series can be used for practically all
assignments, which is why the number of parameters is
quite large. Also, this series offers a choice between two
programming modes - a Menu mode and a Quick menu
mode.
The Quick menu takes the user through a
number of parameters that may be enough to
get the motor to run nearly optimally, if the
factory setting for the other parameters takes the
desired control functions into account, as well as
the configuration of signal inputs/outputs (control
terminals).
The Menu mode makes it possible to select and
change all parameters at the user's option.
3
3
SETUP
1
31