Display Read-Out State; Display Mode; Display Mode - Selection Of Read-Out State - Danfoss VLT Brook Crompton Motor FCM 300 Design Manual

Table of Contents

Advertisement

Programming
3
3
Table 3.2
NOTICE
Pressing [STOP/RESET] will prevent motor from running
also with disconnected LCP 2. Restarting is only possible
via the LCP 2 [START] key.
Table 3.3
NOTICE
If the keys for local control have been selected as active,
they will remain active both when the frequency has
been set for Local Control and for Remote Control via
parameter 002, although with the exception of [FWD/
REV], which is only active in Local operation.
30
®
VLT
DriveMotor FCM Series
[CHANGE DATA] is used for changing the
parameter selected either in the Menu
mode or the Quick menu mode.
[CANCEL] is used if a change of the
selected parameter is not to be carried
out.
[OK] is used for confirming a change of
the parameter selected.
[+]/[-] is used for selecting parameter and
for changing the chosen parameter or for
changing the read out in line 2.
[<][>] is used for selecting group and to
move the cursor when changing
numerical parameters.
[STOP/RESET] is used for stopping or for
resetting the FC motor after a drop-out
(trip). Can be selected via parameter 014
to be active or inactive. If stop is
activated, line 2 will flash, and [START]
must be activated.
[JOG] overrides the output frequency to a
preset frequency while the key is kept
down. Can be selected via parameter 015
to be active or inactive.
[FWD/REV] changes the direction of
rotation of the motor, which is indicated
by means of the arrow on the display
although only in Local. Can be selected
via parameter 016 to be active or inactive
(parameter 013 must be set to [1] or [3]
and parameter 200 set to [1].
[START] is used for starting the FC motor
after stop via the [Stop] key. Is always
active, but cannot override a stop
command given via the terminal strip.
MG03BA02 - VLT
NOTICE
If no external stop function has been selected and the
[STOP] key has been selected as inactive via parameter
014, the FC motor can be started and can only be
stopped by disconnecting the voltage to the motor.

3.1.8 Display Read-out State

The display read-out state can be varied - see
3.1.15 Parameter Groups - depending on whether the FC
motor is in normal operation or is being programmed.

3.1.9 Display Mode

In normal operation, up to 4 different operating variables
can be indicated continuously: 1.1 and 1.2 and 1.3 and 2,
and in line 4 the present operating status or alarms and
warnings that have arisen.
VAR 1.1 VAR 1.2 VAR 1.3
VAR 2
STATUS
Illustration 3.7
3.1.10 Display Mode - Selection of Read-
out State
There are three options in connection with the choice of
read-out state in the Display mode - I, II and III. The choice
of read-out state determines the number of operating
variables read out.
Read-out
I:
state:
Line 1
Description for
operating
variable in line
2
Table 3.4
Table 3.5 gives the units linked to the variables in the first
and second line of the display (see parameter 009).
®