Servo test

Function test of Servo 1 ... 8
mc
This option is available as standard on the
mc-20
transmitter only.
16 20
 
Use the selection keys on the left or right
four-way button to scroll to the menu op-
tion »Servo test« menu option in the multi-function
menu:
MP3 player
Basic settings
Ser vo display
Ser vo test
Code lock
Info display
Tap briefly on the center
SET
key of the right four-way
button to open this menu option:
Ser vo test
act
off
1 2 3 4 5 6 7 8
Any of the inputs 1 ... 8 can be activated for the servo
test by selecting with the selection keys of the left
or right four-way button and then briefly tapping the
SET
key of the right four-way button. As soon as you
have set only one of the inputs 1 ... 8 to "active", the
following notice appears at the bottom of the display
screen:
Ser vo test
act
off
1 2 3 4 5 6 7 8
CLR=act./deact.
A simultaneous tap on the  or  selection keys
of the right four-way button (CLEAR) would now start
and stop, for example, a servo test of input "1" with a
cycle time of 0.5 s.
To change cycle time, select the loop symbol at the
bottom right of the display with the selection keys of
the left or right four-way button:
act
off
CLR=act./deact.
Once this value field has been activated with a brief
tap on the center
...
act
off
CLR=act./deact.
0.5s
... the motion cycle can be changed for the value field
shown in inverse video within a range of 0.5 s and
3.0 s in 0.5 s increments. Briefly tap the center
key of the right four-way button to finish time selec-
tion.
Important notice:
The shut-off of the transmitter does not automati-
cally end an active servo test. Therefore, always
stop a servo test manually BEFORE SHUTTING
OFF the transmitter, because the servo test is
other wise restarted after switching on the trans-
mitter again.
0.5s
Ser vo test
1 2 3 4 5 6 7 8
0.5s
SET
key of the right four-way button
Ser vo test
1 2 3 4 5 6 7 8
0.5s
SET
Ser vo test
act
off
1 2 3 4 5 6 7 8
CLR=act./deact.
As soon as the servo test has been started by a
simultaneously tap on the  or  selection keys
of the right four-way button (CLEAR) a window will
open:
Ser vo test
act
S e r v o t e s t a c t .
off
1 2 3 4 5 6 7 8
CLR=act./deact.
The "servo test" function automatically operates the
servos as though the corresponding transmitter con-
trols were being simultaneously and continuously
moved back and forth between -100 % and +100 %
during the preset time. All active mixing and coupling
functions in the respective model memory, therefore,
are effective and the servos move within the specified
servo paths and servo delimitations.
Another tap simultaneously on the  or  selec-
tion keys of the right four-way button (CLEAR) will
terminate the test.
Program description - Servo test
2.5s
2.5s
275