GRAUPNER HoTT MC-16 Series Programming Manual page 248

Table of Contents

Advertisement

RX CURVE
CURVE1 CH
:
02
TYPE :
CURVE2 CH
:
03
TYPE :
CURVE3 CH
:
04
TYPE :
5CH
FUNCTION:SENSOR
Another tap on the center
SET
key of the right four-
way button will close the selection and, with appropri-
ate repetitive taps on the center
ESC
four-way button, a return to the transmitter's basic
display is accomplished.
RX SERVO TEST
RX SERVO TEST
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
TEST
: STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
Value
Explanation
ALL-MAX
Servo travel on the
"+" side for all servo
outputs for the
servo test
ALL-MIN
Servo travel on the
"-" side for all servo
outputs for the
servo test
TEST
Test procedure
ALARM
Alarm threshold
VOLT
of the receiver
undervoltage
warning
248 Program description - Telemetry
ALARM
TEMP+
A
A
ALARM
B
TEMP–
key of the left
CH
OUTPUT
TYPE
ALL-MAX (servo travel on the "+" side)
In this line you set the maximum servo travel on the
plus side of the control travel for the servo test.
2000 µs corresponds to the full throw; 1500 µs corre-
sponds to the neutral position.
Make sure that the servos do not overrun mechani-
cally during the test routine.
ALL-MIN (servo travel on the "-" side)
Possible
You adjust the maximum servo travel on the minus
settings
side of the control path for the servo test in this line.
1500 ... 2000 µs
1000 µs corresponds to the full throw; 1500 µs corre-
sponds to the neutral position.
TEST
You start and stop the servo test integrated in the
1500 ... 1000 µs
receivers in this line.
A brief tap on the center
button will open the entry field:
START / STOP
3.0 ... 7.5 V
factory setting:
3.8 V
Now, with one of the selection keys of the right four-
Alarm threshold for
50 ... 80 °C
excessively high
Factory setting:
temperature of the
55 °C
receiver
Alarm threshold
-20 ... +10 °C
for excessively low
Factory setting:
temperature of the
-10 °C
receiver
Channel sequence
ONCE, SAME,
SUMI, SUMO and
SUMD
SET
key of the right four-way
RX SERVO TEST
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
TEST
:
STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
way button, select START:
RX SERVO TEST
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
TEST
:
START
ALARM VOLT : 3.8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
A brief tap on the center
SET
key of the right four-way
button will now start the test run. The input field is
shown as "normal" again:
RX SERVO TEST
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
TEST
: START
ALARM VOLT : 3.8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
To stop the servo test, reactivate the entry field as
described above, select
STOP
and confirm this selec-
tion with the
SET
key of the right four-way button.
ALARM VOLT (receiver undervoltage warning)
The receiver voltage is monitored through ALARM
VOLT. The interval can be adjusted between 3.0 and
7.5 Volt. If the set alarm threshold is undercut, an
acoustic signal is issued (interval peep tone long/
short) and "VOLT.E" blinks in the top right of all »RX
...« displays:
RX SERVO
VOLT.E
OUTPUT CH: 01
REVERSE
: OFF
CENTER
: 1500µsec
TRIM
: –000µsec
TRAVEL–
: 150%
TRAVEL+
: 150%
PERIOD
: 20msec
The parameter "R-VOLT" is also represented inverse-
ly in the »RX DATAVIEW« display: