Settings & Dataview - GRAUPNER HoTT MC-16 Series Programming Manual

Table of Contents

Advertisement

Telemetry
The menus gathered under the heading »Telemetry«
mc-16
can be called up from the
20
HoTT transmitter's basic display with a tap of
about one second duration on the center
the left four-way button. The same menus can, like
other transmitter menus, also be opened in the multi-
function menu with a tap on the center
right four-way button:
Teacher / pupil
Tx. output swap
Profi trim
Trim memor y
Telemetr y
Channel sequence
Basic operation
Operating the »Telemetry« menu is essentially the
mc-16
same as for the remaining
20
HoTT transmitter menus. The few differences are
described in the following:
The  selection keys of the left or right four-way
button can be used to switch between individual
pages of the Telemetry menu. Corresponding direc-
tional indicators can be found at top right of each
display page in the form of angled brackets ( ), refer
to the fi gures below. If only one angled bracket is vis-
ible, you are on either the first or last respective page.
In this case, changing pages is only possible in the
indicated direction.
Menu lines in which parameters can be changed are
identified with the aforementioned angled bracket ( ).
The " " pointer will jump a line forward or back with a
tap on the  selection keys of the left or right four-
way button. Lines to which a jump cannot be made
are unalterable.
In order to change a parameter, briefly touch the
center
SET
key of the right four-way button (the pa-
rameter will be displayed in inverse video), change
the value within the permissible adjustment range via
the selection keys of the right four-way button and
mc-
HoTT and
adopt the value with another tap on the
brief tap on the center
ESC
key of
button will cause a return to the starting position
again.
Now use the  selection keys of the left or right
SET
key of the
four-way button to pick the desired sub-menu. How-
ever, if the message ...
... appears instead of the desired sub-menu after
touching the center
button then no connection has been established with
a receiver. Therefore, switch on your receiver system
or, if applicable reconnect the addressed receiver
mc-
HoTT and
as described on page 87 or 95 or activate it as
described under "Important Notices" on the previous
page.
SET
key. A
ESC
key of the left four-way
C A N ' T
R E C E I V E
D ATA
O K
SET
key of the right four-way
SETTINGS & DATAVIEW
On the first display page of the sub-menu "SETTINGS
& DATAVIEW" of the »Telemetry« menu, overwritten
with ...
RX DATAVIEW
TELEMETRY
TEL.RCV.
RCV CH1
SETTING & DATA VIEW
SENSOR SELECT
RF STATUS VIEW
VOICE TRIGGER
... no settings can be made. This page is only pro-
vided for information:
RX DATAVIEW
S–QUA100%S–dBM–030dBM
S–STR100% R–TEM.+28°C
L PACK TIME 00010msec
R-VOLT
:05.0V
L.R-VOLT:04.5V
SENSOR1 :00.0V
SENSOR2 :00.0V
Value
Explanation
S-QUA
Signal quality in %
S-dBm
Reception power in dBm
S-STR
Signal strength in %
R-TEM.
Receiver temperature in °C
L PACK
Indicates the time in ms in which the
TIME
longest data package is lost during the
transmission from the transmitter to the
receiver
R-VOLT
Current operating voltage of the
receiver in volts
L.R-VOLT
Lowest operating voltage of the receiver
since it was last turned on, in volts
SENSOR1 Indicates values of optional telemetric
sensor 1, in volts and °C
Program description - Telemetry
00°C
00°C
241