3. MINIMUM FLOWRATES FOR SFGLD / SFGRD / SFGM ENGINES

3.1 MAIN COOLING CIRCUIT – TWO CIRCUITS
Engine
SFGLD/SFGRD/SFGM180
SFGLD/SFGRD/SFGM 240
SFGLD/SFGRD/SFGM 360
SFGLD/SFGRD/SFGM 480
SFGLD/SFGRD SFGM /560
3.2 MAIN COOLING CIRCUIT – ONE CIRCUIT
Engine
SFGLD 180
SFGLD 240
SFGLD 360
SFGLD 480
SFGLD 560
PRODUCT INFORMATION
IT-G-A-20-007e
GAS ENGINES – PRESSURE LOSSES AND FLOWRATES
Speed
[rpm]
1200
1500
1800
1200
1500
1800
1200
1500
1800
1200
1500
1800
1200
1500
1800
Speed
[rpm]
1800
1800
1800
1800
1800
2.2.11
INDEX
I
May 2015
O&M_2.002211.810_A_10_2016
Minimum flowrate
3
[m
/h]
20
25
30
25
30
40
40
50
60
50
60
80
60
70
75
Minimum flowrate
3
[m
/h]
40
50
60
80
88
DATE
Dep. 2
Delta P
K
[bar]
0.18
-4
0.28
4.5·10
0.41
0.21
-4
0.30
3.3·10
0.53
0.16
-4
0.25
1.0·10
0.36
0.28
0.40
0.70
-4
1.1·10
0.40
0.54
0.62
Delta P
K
[bar]
-4
0,43
2,7·10
-4
0,30
1,2·10
-5
0,14
3,9·10
-5
0,25
3,9·10
-5
0,30
3,9·10
3/7