Install the fan only if the engine has been approved for fan installation. Likewise, install a drive system
defined by Kohler.
-
If the fan or drive contains any plastic or rubber component, have the fan and drive inspected by a qualified
mechanic after operation or exposure to excessively high temperatures (air temperature of over 120ºC).
-
Replace the fan if indications of excessive corrosion or erosion appear in the fan.
-
For reversible or adjustable pitch fans, make sure the blades are correctly locked in the proper position
prior to operation. Also, inspect the fan prior to operation to ensure that ice and dirt have not accumulated
on the fan to cause potential imbalance of the fan.
Be sure that all fans, fan drives and belts are properly shielded.
-

15. TURBOCHARGERS

CAUTION
Turbochargers are designed specifically for each application. Turbochargers operate at high temperatures,
therefore all inflammable material must be kept away from them. Engines must be shut down and at room
temperature before working on turbochargers or burns will result.

16. ENGINE STORAGE CHEMICALS

DANGER
Protective oils contain a petroleum distillation, which is harmful or fatal if swallowed. Avoid contact with skin,
eyes and clothes. Vapour is harmful and causes irritation of eyes, nose, throat and skin. Use only with adequate
ventilation. Avoid breathing of vapour. Do not take internally. Keep container closed and away from heat.
Always read and observe the <<CAUTION>> labels on the containers. Do not destroy the labels on the
containers.
In general, protective compounds should not be heated over 90ºC. To heat at this temperature, the containers
must be placed in a vessel with hot water. The cover must be removed and a hole must be made in the
container to reduce the danger of explosion. Heating or direct heat is an unnecessary fire risk.

17. FIRE PROTECTION

WARNING
Locate fire extinguishers so that they are easily accessible if a fire start. Carefully maintain records of
extinguisher inspection and recharging to ensure the fire extinguishing capabilities when required. Consult your
fire extinguisher supplier or insurance engineering for recommendations required for the engine installation. It is
also recommended to have well-identified fire emergency escape routes in all engine installations, in