WARNING
Trigger number
Trigger missing
Cycle signal missing
Trigger period
Wrong trigger
Wrong reset
Reset number
Pre-processor pickup trigger
number
Pre-processor trigger missing
Pre-processor pickup Index
missing
Pre-processor pickup
Misfire rate
Overspeed
Low-power
General
Configuration data CRC error
NOTE
There are a number of errors and warnings that match the description. The difference is that when such failures
occur below a rotation speed threshold, it is considered a warning and the unit continues firing. When failure
occurs above this threshold, it is considered an error and the unit cuts out the ignition. This rotation speed
threshold depends on the rated operating conditions the unit is configured to.
3.1.7. Information
This view displays an overview of the ignition unit
PRODUCT INFORMATION
IO-G-M-33-010e
INSTALLATION AND OPERATION MANUAL - GIS IGNITION UNIT
DESCRIPTION
Number of teeth does not coincide with the set number
Number of teeth counted is smaller than expected number
Cam signal was not detected in time. More events were
counted than expected per cycle.
Event period between two teeth was outside the expected
range.
Tooth event recognised as fault
Reset event recognised as fault
Number of reset signals per cycle is outside expected range
Number of events detected in the pre-processor pickup is
outside the expected range
Event period of pre-processor pickup is outside the
expected range
The pre-processor pickup has not been able to detect the
reset/cam signal
Pre-processor pickup causes warning
Limit of misfire events exceeded
Overspeed
Voltage too low
General warning
The configuration could not be read due to a CRC error