3. Inspect the inside of the filter casing and clean it with a moistened rag. Also check the exhaust valve at the
bottom of the filter and eliminate possible dirt build-ups or condensates
4. Verify the condition and appearance of the main filter cartridge: the filtering paper should be free from
excessive dirt or breakage. Check the paper folds for homogeneous distribution and absence of deformation.
Clean the filter cartridge in case of high dust concentration or if specified by the maintenance programme
(see point 2.2).
Front sealing ring
Locknut
For radially sealed filters, inspecting the main filtering cartridge will imply the following sequence of operations:
1. Release the metal latches and remove the cover.
2. Extract the main filter cartridge from the filter, avoiding impacts of the cartridge against the casing.
3. Inspect the inside of the filter casing and clean it with a moistened rag. Also check the exhaust valve at the
bottom of the filter and eliminate possible dirt build-ups or condensates.
PRODUCT INFORMATION
IO-C-M-35-001e
S.C. washer
Main cartridge
M.C.
washer
Fig. 1 - Exploded view of a tangentially sealed air filter
INDEX
E
AIR FILTERS. MAINTENANCE
Intake cap
Safety cartridge
5.2.46
DATE
September 2016
O&M_2.002211.810_A_10_2016
Fouling
detector
Clamp
Filter casing
Integrated axial
sealing gaskets
Dep. 2
2/6