Notes
Sound power levels obtained as per the ISO 9614-2 standard.
-
Sound pressure levels measured at 1 m from the engine, calculated as per the UNE-EN ISO-11203:1996
-
standard.
The uncertainty of the results is for class 3 determinations with a maximum standard deviation of  =
-
dB(A).
4. NOISE EMISSION AT 1500 RPM
The following table shows the sound pressure distribution in octave frequency bands and the total sound level
with the engine running continuously at 1500 rpm and at 100% power.
F/SFGLD/SFGM ENGINES
63
125
250
500
1000
2000
4000
LpA,  dB(A)
HGM ENGINES
63
125
250
500
1000
2000
4000
LpA,  dB(A)
Notes
-
Sound power levels obtained as per the ISO 9614-2 standard.
-
Sound pressure levels measured at 1 m from the engine, calculated as per the UNE-EN ISO-11203:1996
standard.
The uncertainty of the results is for class 3 determinations with a maximum standard deviation of  =
-
dB(A).
PRODUCT INFORMATION
IC-G-D-00-043e
SOUND PRESSURE LEVEL
IN THE GAS ENGINES EXHAUST AREA
180
240
97
99
118
121
124
127
113
116
112
115
110
114
106
109
126
128
240
420
105
100
121
119
129
129
116
116
116
115
115
113
112
111
130
130
1.22
INDEX
DATE
F
July 2016
O&M_2.002211.810_A_10_2016
360
480
100
98
121
124
126
125
119
124
117
121
115
119
110
111
129
130
560
102
122
128
122
119
117
112
130
Dep. 2
4
560
102
121
125
122
118
115
109
129
4