Kohler SFGLD480 Operation & Maintenance Manual page 238

Generator set models 750/1000rezk
Table of Contents

Advertisement

Job
Interval
250 h
E0
or
6 months
500 h
E1
or
once a year
1,500 h
E2
or
3 years
- The spark plugs change must be made attending the IO-G-M-33-007 product information.
*It is recommended cylinder endoscope revision and compression test when the spark-plug change
NOTE
- Ask Kohler to use another oil that it is not KOHLER MOTOROIL.
PRODUCT INFORMATION
IO-G-M-00-019e
MAINTENANCE OF NATURAL GAS ENGINE SFGLD
Job Description
- Analyse waste oil
- Check and refill additive level in coolant
- Change oil KOHLER MOTOROIL (oil sump and cooler)
- Change oil filters
- Clean the oil centrifuge filter, film-thickness measurement and change the paper filter
- Clean the metallic sponge of the oil purifier
- Measure crankcase pressure
- Check air/fuel ratio
- Adjust air/fuel ratio to full load (*), if necessary
- Inspect the air filters
- Adjustment of rocker arms and valve lifters. Measure valve height
- Verify the ignition timing
- Check battery and starter connections
- Inspection of high voltage wires of the ignition system
- Change the filter of crankcase gases recirculation system and clean this circuit (*
- Check gas filters
- Change hoses and clamps.
- Test thermostats of coolant circuit.
- Test control and safety devices: temperature and pressure switches and probes
- Check damper temperature
- Change air filters
- Check gaskets in the rocker arm covers
- Disassemble, clean and adjust all the speed and ignition pick-ups
- Measure the exhaust back-pressure
- Change coolant
- Verify the tightening torque of knocking sensors on stud head (20 Nm)
- Check axial and Radial allowance of turbochargers
5.1.16
INDEX
DATE
G
January 2016
STAND-BY
O&M_2.002211.810_A_10_2016
Dep. 2
A
*)
4/6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sfgld360

Table of Contents