®
ABB i-bus
EIB / KNX
© 2006 ABB STOTZ-KONTAKT GmbH
Project design and programming
The staircase lighting function is triggered by switching the button on/off
(telegram with value "1").
A renewed telegram received with the value "1" during the dimming phase
has no effect. A "1" telegram in the hold phase (30 seconds) means that the
hold phase (30 seconds) will run again (retriggering). The same effect
results if a "1" telegram is received in the warning phase. In this case the
hold time (30 seconds) is restarted.
The lamps switch off after the warning time.
75