Parameter Lists
Par. No.
Parameter description
#
SP-89
Decel Time 3 S-ramp Ratio at Decel. Start
SP-9#
SP-90
Decel Time 3 S-ramp Ratio at Decel. End
SP-92
Accel/Decel Ramp 4 Type
SP-95
Accel Time 4 S-ramp Ratio at Accel. Start
SP-96
Accel Time 4 S-ramp Ratio at Accel. End
4
4
SP-97
Decel Time 4 S-ramp Ratio at Decel. Start
SP-98
Decel Time 4 S-ramp Ratio at Decel. End

4.1.10 O-## Options/Comms

Par. No.
Parameter description
#
O-0#
O-01
Control Site
O-02
Control Word Source
O-03
Control Word Timeout Time
O-04
Control Word Timeout Function
O-05
End-of-Timeout Function
O-06
Reset Control Word Timeout
O-07
Diagnosis Trigger
O-08
Readout Filtering
O-1#
O-10
Control Word Profile
O-13
Configurable Status Word STW
O-14
Configurable Control Word CTW
O-19
Product Code
O-3#
O-30
Protocol
O-31
Address
O-32
Drive Port Baud Rate
O-33
Drive Port Parity
O-34
Estimated cycle time
O-35
Minimum Response Delay
O-36
Max Response Delay
O-37
Max Inter-Char Delay
O-4#
O-40
Telegram Selection
O-41
Parameters for Signals
O-42
PCD Write Configuration
O-43
PCD Read Configuration
O-5#
O-50
Coasting Select
O-51
Quick Stop Select
O-52
DC Brake Select
O-53
Start Select
O-54
Reversing Select
O-55
Set-up Select
O-56
Preset Reference Select
O-57
Profidrive OFF2 Select
150
AF-650 GP Programming Guide
Default value
50 %
50 %
[0] Linear
50 %
50 %
50 %
50 %
Default value
[0] Digital and ctrl.word
ExpressionLimit
1 s
ExpressionLimit
[1] Resume set-up
[0] Do not reset
[0] Disable
ExpressionLimit
[0] Drive Profile
ExpressionLimit
[1] Profile default
ExpressionLimit
[2] Modbus RTU
1 N/A
ExpressionLimit
[0] Even Parity, 1 Stop Bit
0 ms
10 ms
ExpressionLimit
ExpressionLimit
[1] Standard telegram 1
0
ExpressionLimit
ExpressionLimit
[3] Logic OR
[3] Logic OR
ExpressionLimit
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
DET-618C
4-set-up
Change
Conver-
during
sion
operation
index
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
4-set-up
Change
Conver-
during
sion
operation
index
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
-1
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
0
1 set-up
TRUE
1 set-up
TRUE
0
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
-3
All set-ups
TRUE
-3
1 set-up
TRUE
-3
1 set-up
TRUE
-5
2 set-ups
TRUE
All set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Type
-
Uint8
-
Uint8
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
Uint32
-
Uint8
Uint8
-
Uint8
-
Uint8
Uint32
Uint16
Uint16
Uint16
-
Uint8
-
Uint16
-
Uint16
-
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8