Sp-## Special Functions - GE AF-650 GP Programming Manual

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Lists

4.1.9 SP-## Special Functions

Par. No.
Parameter description
#
SP-0#
SP-00
Fault Level
SP-1#
SP-10
Line failure
SP-11
Line Voltage at Input Fault
SP-12
Function at Line Imbalance
SP-13
Mains Failure Step Factor
SP-14
Kin. Backup Time Out
SP-15
Kin. Backup Trip Recovery Level
SP-2#
SP-23
Typecode Setting
SP-24
Trip Delay at Current Limit
SP-25
Trip Delay at Torque Limit
SP-26
Trip Delay at Drive Fault
SP-28
Production Settings
SP-29
Service Code
SP-3#
SP-30
Current Lim Cont, Proportional Gain
SP-31
Current Lim Contr, Integration Time
SP-32
Current Lim Ctrl, Filter Time
SP-35
Stall Protection
SP-4#
SP-40
VT Level
SP-41
Energy Savings Min. Magnetisation
SP-42
Energy Savings Min. Frequency
SP-43
Motor Cosphi
SP-5#
SP-50
RFI Filter
SP-51
DC Link Compensation
SP-52
Fan Operation
SP-53
Fan Monitor
SP-55
Output Filter
SP-56
Capacitance Output Filter
SP-57
Inductance Output Filter
SP-59
Actual Number of Inverter Units
SP-7#
SP-71
Accel Time 1 S-ramp Ratio at Accel. Start
SP-72
Accel Time 1 S-ramp Ratio at Accel. End
SP-73
Decel Time 1 S-ramp Ratio at Decel. Start
SP-74
Decel Time 1 S-ramp Ratio at Decel. End
SP-76
Accel/Decel Time 2 Type
SP-79
Accel Time 2 S-ramp Ratio at Accel. Start
SP-8#
SP-80
Accel Time 2 S-ramp Ratio at Accel. End
SP-81
Decel Time 2 S-ramp Ratio at Decel. Start
SP-82
Decel Time 2 S-ramp Ratio at Decel. End
SP-84
Accel/Decel Ramp 3 Type
SP-87
Accel Time 3 S-ramp Ratio at Accel. Start
SP-88
Accel Time 3 S-ramp Ratio at Accel. End
AF-650 GP Programming Guide
Default value
ExpressionLimit
[0] No function
ExpressionLimit
[0] Trip
1 N/A
60 s
ExpressionLimit
ExpressionLimit
60 s
60 s
ExpressionLimit
[0] No action
0 N/A
100 %
ExpressionLimit
ExpressionLimit
[1] Enabled
66 %
ExpressionLimit
10 Hz
ExpressionLimit
[1] On
ExpressionLimit
[0] Auto
[1] Warning
[0] No Filter
ExpressionLimit
ExpressionLimit
ExpressionLimit
50 %
50 %
50 %
50 %
[0] Linear
50 %
50 %
50 %
50 %
[0] Linear
50 %
50 %
DET-618C
4-set-up
Change
Conver-
during
sion
operation
index
1 set-up
TRUE
All set-ups
FALSE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-1
All set-ups
TRUE
0
All set-ups
TRUE
-3
2 set-ups
FALSE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
FALSE
0
All set-ups
FALSE
-3
All set-ups
TRUE
-4
All set-ups
FALSE
All set-ups
FALSE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-2
1 set-up
FALSE
-
1 set-up
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
FALSE
-7
All set-ups
FALSE
-6
1 set-up
FALSE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
Type
-
Uint8
Uint8
4
4
Uint16
Uint8
Uint8
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint16
-
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
149