Parameter Descriptions
LC-52 Logic Controller Action
Array [20]
Option:
Function:
[14] Select preset ref
Selects preset reference 4.
4
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a Network.
[15] Select preset ref
Selects preset reference 5.
5
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a Network.
[16] Select preset ref
Selects preset reference 6.
6
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a Network.
[17] Select preset ref
Selects preset reference 7.
7
If the active preset reference is changed,
it will merge with other preset reference
commands coming from either the digital
inputs or via a Network.
[18] Select Accel/
Selects ramp 1.
Decel 1
[19] Select Accel/
Selects ramp 2.
Decel 2
[20] Select Accel/
Selects ramp 3.
Decel 3
[21] Select Accel/
Selects ramp 4.
Decel 4
[22] Run
Issues a start command to the frequency
converter.
[23] Run reverse
Issues a start reverse command to the
frequency converter.
[24] Stop
Issues a stop command to the frequency
converter.
[25] Qstop
Issues a quick stop command to the
frequency converter.
[26] Dcstop
Issues a DC stop command to the
frequency converter.
[27] Coast
The frequency converter coasts
immediately. All stop commands
including the coast command stop the
Logic Controller.
[28] Freeze output
Freezes the output frequency of the
frequency converter.
[29] Start timer 0
Starts timer 0, see LC-20 Logic Controller
Timer for further description.
[30] Start timer 1
Starts timer 1, see LC-20 Logic Controller
Timer for further description.
AF-650 GP Programming Guide
LC-52 Logic Controller Action
Array [20]
Option:
[31] Start timer 2
[32] Set digital out A
low
[33] Set digital out B
low
[34] Set digital out C
low
[35] Set digital out D
low
[36] Set digital out E
low
[37] Set digital out F
low
[38] Set digital out A
high
[39] Set digital out B
high
[40] Set digital out C
high
[41] Set digital out D
high
[42] Set digital out E
high
[43] Set digital out F
high
[60] Reset Counter A Resets Counter A to zero.
[61] Reset Counter B Resets Counter B to zero.
[70] Start timer 3
[71] Start timer 4
[72] Start timer 5
[73] Start timer 6
[74] Start timer 7
DET-618C
Function:
Starts timer 2, see LC-20 Logic Controller
Timer for further description.
Any output with LC output A will be low.
Any output with LC output B will be low.
Any output with LC output Cwill be low.
Any output with LC output D will be low.
Any output with LC output E will be low.
Any output with LC output F will be low.
Any output with LC output A will be
high.
Any output with LC output B will be
high.
Any output with LC output C will be
high.
Any output with LC output D will be
high.
Any output with LC output E will be
high.
Any output with LC output Fwill be high.
Start Timer 3, see LC-20 Logic Controller
Timer for further description.
Start Timer 4, see LC-20 Logic Controller
Timer for further description.
Start Timer 5, see LC-20 Logic Controller
Timer for further description.
Start Timer 6, see LC-20 Logic Controller
Timer for further description.
Start Timer 7, see LC-20 Logic Controller
Timer for further description.
3
3
127