Parameter Descriptions

3.18 DR-## Data Read-outs

Parameter group related to data readouts in the drive for
references, voltages, control, alarms, warnings, and status
words.
3.18.1 DR-0# General Status
Parameters to view the calculated references, the active
control word, and status word.
DR-00 Control Word
Range:
Function:
0
[0 - 65535] View the Control word sent from the frequency
*
converter via the serial communication port in
hex code.
DR-01 Reference [Unit]
Range:
0 ReferenceFeed-
[-999999 - 999999
backUnit
ReferenceFeed-
*
backUnit]
DR-02 Reference [%]
Range:
Function:
0 %
[-200 - 200
View the total reference. The total
*
%]
reference is the sum of digital, analog,
preset, bus, and freeze references, plus
catch-up and slow-down.
DR-03 Status Word
Range:
Function:
0
[0 - 65535] View the Status word sent from the frequency
*
converter via the serial communication port in
hex code.
DR-05 Main Actual Value [%]
Range:
Function:
0 %
[-100 - 100 %] View the two-byte word sent with the
*
Status word to the bus Master reporting
the Main Actual Value.
DR-09 Custom Readout
Range:
0 CustomRea-
[0 - 0 CustomRea-
doutUnit
doutUnit]
*
AF-650 GP Programming Guide
3.18.2 DR-1# Motor Status
Parameters to view the motor status values.
0 kW
0 hp
Function:
View the present
reference value applied
on impulse or analog
basis in the unit
resulting from the
configuration selected
in H-40 Configuration
Mode (Hz, Nm or RPM).
0 V
0 Hz
0 A
0 %
Function:
View the value of
custom readout from
K-30 Unit for Custom
Readout to K-32 Max
Value of Custom Readout
DET-618C
DR-10 Power [kW]
Range:
Function:
[0 -
Displays motor power in kW. The value
*
10000 kW]
shown is calculated on the basis of the actual
motor voltage and motor current. The value
is filtered, and therefore approx. 30 ms may
pass from when an input value changes to
when the data read-out values change. The
resolution of read-out value on fieldbus is in
10 W steps.
DR-11 Power [hp]
Range:
Function:
[0 - 10000
View the motor power in HP. The value
*
hp]
shown is calculated on the basis of the
actual motor voltage and motor current. The
value is filtered, and therefore approximately
30 ms may pass from when an input value
changes to when the data read-out values
change.
DR-12 Motor Voltage
Range:
Function:
[0 - 6000 V] View the motor voltage, a calculated value
*
used for controlling the motor.
DR-13 Frequency
Range:
Function:
[0 - 6500 Hz] View the motor frequency, without
*
resonance dampening.
DR-14 Motor current
Range:
Function:
[0 - 10000
View the motor current measured as a mean
*
A]
value, I
. The value is filtered, and thus
RMS
approximately 30 ms may pass from when
an input value changes to when the data
read-out values change.
DR-15 Frequency [%]
Range:
Function:
[-100 -
View a two-byte word reporting the actual
*
100 %]
motor frequency (without resonance
dampening) as a percentage (scale 0000-4000
Hex) of F-03 Max Output Frequency 1. Set
PB-16 PCD Read Configuration index 1 to send
it with the Status Word instead of the MAV.