Parameter Descriptions
LC-10 Comparator Operand
Array [6]
Option:
[53]
Drive ready
3
3
[54]
Running
[55]
Reversing
[56]
In range
[60]
On reference
[61]
Below reference,
low
[62]
Above ref, high
[65]
Torque limit
[66]
Current Limit
[67]
Out of current
range
[68]
Below I low
[69]
Above I high
[70]
Out of speed
range
[71]
Below speed low
[72]
Above speed high
[75]
Out of feedback
range
[76]
Below feedback
low
[77]
Above feedback
high
[80]
Thermal warning
122
AF-650 GP Programming Guide
Function:
The frequency converter is ready for
operation and applies a supply signal
on the control board.
The motor is running.
The output is high when the
frequency converter is running
counter clockwise (the logical product
of the status bits "running" AND
"reverse").
The motor is running within the
programmed current and speed
ranges set in H-70 Warning Current
Low to H-73 Warning Speed High.
The motor is running on reference.
The motor is running below the value
given in H-74 Warning Reference Low.
The motor is running above the value
given in H-75 Warning Reference High
The torque limit, set in F-40 Torque
Limiter (Driving) or F-41 Torque Limiter
(Braking), has been exceeded.
The motor current limit, set in
F-43 Current Limit, has been exceeded.
The motor current is outside the
range set in F-43 Current Limit.
The motor current is lower than set in
H-70 Warning Current Low.
The motor current is higher than set
in H-71 Warning Current High.
The speed is outside the range set in
H-72 Warning Speed Low and
H-73 Warning Speed High.
The output speed is lower than the
setting in H-72 Warning Speed Low.
The output speed is higher than the
setting in H-73 Warning Speed High.
The feedback is outside the range set
in H-76 Warning Feedback Low and
H-77 Warning Feedback High.
The feedback is below the limit set in
H-76 Warning Feedback Low.
The feedback is above the limit set in
H-77 Warning Feedback High.
The thermal warning turns on when
the temperature exceeds the limit in
LC-10 Comparator Operand
Array [6]
Option:
[82]
Mains out of range The mains voltage is outside the
[85]
Warning
[86]
Alarm (trip)
[87]
Alarm (trip lock)
[90]
Bus OK
[91]
Torque limit &
stop
[92]
Brake fault (IGBT)
[93]
Mech. brake
control
[94]
Safe stop active
[100] Comparator 0
[101] Comparator 1
[102] Comparator 2
[103] Comparator 3
[104] Comparator 4
[105] Comparator 5
[110] Logic rule 0
[111] Logic rule 1
[112] Logic rule 2
[113] Logic rule 3
[114] Logic rule 4
[115] Logic rule 5
[120] Logic Controller
Time-out 0
[121] Logic Controller
Time-out 1
[122] Logic Controller
Time-out 2
[123] Logic Controller
Time-out 3
[124] Logic Controller
Time-out 4
[125] Logic Controller
Time-out 5
[126] Logic Controller
Time-out 6
[127] Logic Controller
Time-out 7
[130] Digital input DI18
DET-618C
Function:
the motor, the frequency converter,
the brake resistor or thermistor.
specified voltage range.
A warning is active.
A (trip) alarm is active.
A (Trip lock) alarm is active.
Active communication (no time-out)
via the serial communication port.
If the frequency converter has
received a stop signal and is at the
torque limit, the signal is logic "0".
The brake IGBT is short circuited.
The mechanical brake is active.
The result of comparator 0.
The result of comparator 1.
The result of comparator 2.
The result of comparator 3.
The result of comparator 4.
The result of comparator 5.
The result of Logic rule 0.
The result of Logic rule 1.
The result of Logic rule 2.
The result of Logic rule 3.
The result of Logic rule 4.
The result of Logic rule 5.
The result of LC timer 0.
The result of LC timer 1.
The result of LC timer 2.
The result of LC timer 3.
The result of LC timer 4.
The result of LC timer 5.
The result of LC timer 6.
The result of LC timer 7.
Digital input 18. High = True.