Introduction
1
1
1 Introduction
1.1 Software Version
This Programming Guide can be used for all AF-650 GP
frequency converters with software version 2.31.
The software version number can be seen from ID-43 Software
Version.
Table 1.1 Software Version
1.2 Approvals
Table 1.2 Approvals
1.3 Symbols
The following symbols are used in this manual.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may
also be used to alert against unsafe practices.
CAUTION
Indicates a situation that may result in equipment or
property-damage-only accidents.
NOTE
Indicates highlighted information that should be regarded
with attention to avoid mistakes or operate equipment at
less than optimal performance.
4
AF-650 GP Programming Guide
Programming Guide
Software version: 2.31
1.4 Definitions
1.4.1 Frequency Converter
I
DRIVE,MAX
Maximum output current.
I
DRIVE,N
Rated output current supplied by the frequency converter.
U
DRIVE,MAX
Maximum output voltage.
1.4.2 Input
Control command
Start and stop the connected motor by means of keypad
and digital inputs.
Functions are divided into two groups.
Functions in group 1 have higher priority than functions in
group 2.
Group 1
Reset, Coasting stop, Reset and Coasting stop,
Quick-stop, DC braking, Stop and the [OFF] key.
Group 2
Start, Pulse start, Reversing, Start reversing, Jog
and Freeze output
1.4.3 Motor
Motor Running
Torque generated on output shaft and speed from zero
rpm to max. speed on motor.
f
JOG
Motor frequency when the jog function is activated (via
digital terminals).
f
M
Motor frequency.
f
MAX
Maximum motor frequency.
f
MIN
Minimum motor frequency.
f
M,N
Rated motor frequency (nameplate data).
I
M
Motor current (actual).
I
M,N
Rated motor current (nameplate data).
n
M,N
Rated motor speed (nameplate data).
DET-618C