Parameter Descriptions
[1200] Control Word
Present control word
[1201] Reference [Unit]
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in selected unit.
[1202] Reference %
Total reference (sum of digital/
analog/preset/bus/freeze ref./catch
up and slow-down) in percent.
[1203] Status Word
Present status word.
[1205] Main Actual Value
Actual value as a percentage.
[%]
[1209] Custom Readout
[1210] Power [kW]
Actual power consumed by the
motor in kW.
[1211] Power [hp]
Actual power consumed by the
motor in HP.
[1212] Motor Voltage
Voltage supplied to the motor.
[1213] Frequency
Motor frequency, i.e. the output
frequency from the frequency
converter in Hz
[1214] Motor Current
Phase current of the motor
measured as effective value.
[1215] Frequency [%]
Motor frequency, i.e. the output
frequency from the frequency
converter in percent.
[1216] Torque
Actual motor torque in Nm
[1217] Speed [RPM]
Speed in RPM (revolutions per
minute) i.e. the motor shaft speed in
closed loop.
[1218] Motor Thermal
Thermal load on the motor,
calculated by the Electronic Thermal
Overload function.
[1219] KTY Sensor
Temperature
[1220] Motor Angle
[1221] Phase Angle
[1222] Torque %
Present motor load as a percentage
of the rated motor torque.
[1230] DC Link Voltage
Intermediate circuit voltage in the
frequency converter.
[1232] BrakeEnergy/s
Present brake power transferred to
an external brake resistor.
Stated as an instantaneous value.
[1233] BrakeEnergy/2 min
Brake power transferred to an
external brake resistor. The mean
power is calculated continuously for
the most recent 120 seconds.
[1234] Heatsink Temp.
Present heat sink temperature of the
frequency converter. The cut-out
limit is 95 ±5 ±°C; cutting back in
occurs at 70 ±5° C.
[1235] Inverter Thermal
Percentage load of the inverters.
[1236] Inv. Nom. Current
Nominal current of the frequency
converter.
[1237] Inv. Max. Current
Maximum current of the frequency
converter.
AF-650 GP Programming Guide
[1238] Logic Controller
[1239] Control Card Temp. Temperature of the control card.
[1250] External Reference
[1251] Pulse Reference
[1252] Feedback [Unit]
[1253] Digi Pot Reference
[1260] Digital Input
[1261] Terminal 53 Switch
[1262] Analog Input 53
[1263] Terminal 54 Switch
[1264] Analog Input 54
[1265] Analog Output 42
[1266] Digital Output [bin] Binary value of all digital outputs.
[1267] Freq. Input #29 [Hz] Actual value of the frequency
[1268] Freq. Input #33 [Hz] Actual value of the frequency
[1269] Pulse Output #27
[1270] Pulse Output #29
[1271] Relay Output [bin]
[1272] Counter A
[1273] Counter B
[1274] Prec. Stop Counter
[1275] Analog input
[1276] Analog input
[1277] Analog output
[1280] Fieldbus CTW 1
[1282] Fieldbus REF 1
DET-618C
State of the event executed by the
State
control.
Sum of the external reference as a
percentage, i.e. the sum of analog/
pulse/bus.
Frequency in Hz connected to the
digital inputs (18, 19 or 32, 33).
Reference value from programmed
digital input(s).
Signal states form the 6 digital
terminals (18, 19, 27, 29, 32 and 33).
Input 18 corresponds to the bit at
the far left. Signal low = 0; Signal
high = 1.
Setting of input terminal 54. Current
Setting
= 0; Voltage = 1.
Actual value at input 53 either as a
reference or protection value.
Setting of input terminal 54. Current
Setting
= 0; Voltage = 1.
Actual value at input 54 either as
reference or protection value.
Actual value at output 42 in mA.
[mA]
Use AN-50 Terminal 42 Output to
select the value to be shown.
applied at terminal 29 as an impulse
input.
applied at terminal 33 as an impulse
input.
Actual value of impulses applied to
[Hz]
terminal 27 in digital output mode.
Actual value of impulses applied to
[Hz]
terminal 29 in digital output mode.
Application dependent (e.g. LC
Control)
Application dependent (e.g. LC
Control)
Display the actual counter value.
Actual value at input X30/11 either
X30/11
as reference or protection value.
Actual value at input X30/12 either
X30/12
as reference or protection value.
Actual value at output X30/8 in mA.
X30/8 mA
Use AN-60 Terminal X30/8 Output to
select the value to be shown.
Control word (CTW) received from
the Bus Master.
Main reference value sent with
control word from the Bus Master.
3
3
27