GE AF-650 GP Programming Manual page 90

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions
O-35 Minimum Response Delay
Range:
Function:
10 ms
[1 - 10000 ms] Specify the minimum delay time
*
between receiving a request and
transmitting a response. This is used for
overcoming modem turnaround delays.
O-36 Max Response Delay
Range:
Function:
10001 ms
[11 - 10001
Specify the maximum permissible
*
ms]
delay time between transmitting a
request and receiving a response. If a
response from the frequency converter
is exceeding the time setting then it
will be discarded.
O-37 Max Inter-Char Delay
Range:
Function:
25.00 ms
[0.00 -
Specify the maximum permissible time
*
35.00 ms]
interval between receipt of two bytes.
This parameter activates time-out if
transmission is interrupted.
This parameter is active only when
O-30 Protocol is set to [1] Drive MC
protocol.
3.10.4 O-4# Drive MC Port Settings
Parameters to configure the standard telegram or custom
telegram for the GE drive port.
O-40 Telegram Selection
Option:
Function:
[1]
Standard telegram 1 Enables use of freely configurable
*
messages or standard messages for
the Drive port.
[100] None
[101] PPO 1
[102] PPO 2
[103] PPO 3
[104] PPO 4
[105] PPO 5
[106] PPO 6
[107] PPO 7
[108] PPO 8
[200] Custom telegram 1
Enables use of freely configurable
messages or standard messages for
the Drive port.
[202] Custom telegram 3
O-41 Parameters for Signals
Option:
[0]
None
*
AF-650 GP Programming Guide
O-41 Parameters for Signals
Option:
[7]
[8]
[15]
[16]
[17]
[18]
[40]
[41]
[52]
[53]
[62]
[110]
[111]
[190]
[193]
[195]
[197]
[222]
[223]
[515]
[653]
[663]
[748]
[890]
[891]
[1201] Reference [Unit]
[1202] Reference %
[1203] Status Word
[1205] Main Actual Value [%]
[1209] Custom Readout
[1210] Power [kW]
[1211] Power [hp]
[1212] Motor Voltage
[1213] Frequency
[1214] Motor current
[1215] Frequency [%]
[1216] Torque [Nm]
[1217] Speed [RPM]
[1218] Motor Thermal
[1219] KTY sensor temperature
[1220] Motor Angle
[1221] Torque [%] High Res.
[1222] Torque [%]
[1225] Torque [Nm] High
[1230] DC Link Voltage
Function:
[1232] Brake Energy /s
This parameter contains
[1233] Brake Energy /2 min
a list of signals available
[1234] Heatsink Temp.
DET-618C
Accel Time 1
Decel Time 1
Motor Speed High Limit [Hz]
Motor Speed Low Limit [Hz]
Motor Speed High Limit [RPM]
Motor Speed Low Limit [RPM]
Torque Limiter (Driving)
Torque Limiter (Braking)
Minimum Reference
Maximum Reference
Catch up/slow Down Value
Accel Time 2
Decel Time 2
Digital & Relay Bus Control
Pulse Out #27 Bus Control
Pulse Out #29 Bus Control
Pulse Out #X30/6 Bus Control
Jog Accel/Decel Time
Quick Stop Decel Time
Readout: actual setup
Terminal 42 Output Bus Control
Terminal X30/8 Bus Control
PCD Feed Forward
Bus Jog 1 Speed
Bus Jog 2 Speed
Function:
for selection in O-42 PCD
Write Configuration and
O-43 PCD Read Configu-
3
ration.
89
3

Hide quick links:

Advertisement

Table of Contents
loading