Advertisement

Parameter Descriptions
PB-44 Fault Message Counter
Range:
Function:
capacity is eight error events. The buffer and
counter are set to 0 upon reset or power-up.
PB-45 Fault Code
Range:
Function:
0
[0 - 0] This buffer contains the alarm word for all alarms
*
and warnings that have occurred since last reset or
power-up. The maximum buffer capacity is eight
error events.
PB-47 Fault Number
Range:
Function:
0
[0 - 0] This buffer contains the alarm number (e.g. 2 for
*
live zero error, 4 for mains phase loss) for all alarms
and warnings that have occurred since last reset or
power-up. The maximum buffer capacity is eight
error events.
PB-52 Fault Situation Counter
Range:
Function:
0
[0 - 1000] This parameter displays the number of error
*
events which have occurred since last reset of
power-up.
PB-53 Profibus Warning Word
Range:
Function:
0
[0 - 65535] This parameter displays Profibus communication
*
warnings. Refer to the Profibus Operating
Instructions for further information.
Read only
Bit
Meaning
0
Connection with DP-master is not ok
1
Not used
2
(Network Data link Layer) is not ok
3
Clear data command received
4
Actual value is not updated
5
Baudrate search
6
PROFIBUS ASIC is not transmitting
7
Restore of PROFIBUS is not ok
8
Frequency converter is tripped
9
Internal CAN error
10
Wrong configuration data from PLC
11
Wrong ID sent by PLC
12
Internal error occured
13
Not configured
14
Timeout active
15
Warning 34 active
Table 3.26
AF-650 GP Programming Guide
PB-63 Actual Baud Rate
Option:
[0]
[1]
[2]
[3]
[4]
[6]
[7]
[8]
[9]
[10]
[11]
[255]
*
PB-64 Device Identification
Range:
0
[0 - 0] This parameter displays the device identification.
*
PB-65 Profile Number
Range:
0
[0 - 0] This parameter contains the profile identification.
*
NOTE
This parameter is not visible via keypad.
PB-67 Control Word 1
Range:
0
[0 - 65535] This parameter accepts the Control Word from a
*
PB-68 Status Word 1
Range:
0
[0 - 65535] This parameter delivers the Status Word for a
*
DET-618C
Function:
This parameter displays the actual
Profibus baud rate. The Profibus
Master automatically sets the baud
rate.
9,6 kbit/s
19,2 kbit/s
93,75 kbit/s
187,5 kbit/s
500 kbit/s
1500 kbit/s
3000 kbit/s
6000 kbit/s
12000 kbit/s
31,25 kbit/s
45,45 kbit/s
No baudrate found
Function:
Refer to the Operating Instructions for Profibus, for
further explanation.
Function:
Byte 1 contains the profile number and byte 2 the
version number of the profile.
Function:
Master Class 2 in the same format as PCD 1.
Function:
Master Class 2 in the same format as PCD 2.
3
3