3.13 EN-## Ethernet

The parameters in this group are common for Ethernet IP
and Modbus TCP.
EN-00 IP Address Assignment
3
3
Option:
[0]
Manual IP-address can be set in EN-01 IP Address IP
*
[1]
DHCP
[2]
BOOTP IP-address is assigned via BOOTP server.
EN-01 IP Address
Range:
[000.000.000.000 -
255.255.255.255]
EN-02 Subnet Mask
Range:
[000.000.000.000 -
255.255.255.255]
EN-03 Default Gateway
Range:
[000.000.000.000 –
255.255.255.255]
EN-04 DHCP Server
Range:
[000.000.000.000 –
255.255.255.255]
NOTE
A power-cycle is necessary after setting the IP parameters
manually.
EN-05 Lease Expires
Range:
0
[0 - 0] Read only. Displays the lease-time left for the
*
current DHCP-assigned IP address.
EN-06 Name Servers
Range:
0
[0 - 2147483647] IP addresses of Domain Name Servers.
*
102
Function:
Selects the IP Address assignment method.
Address.
IP-address is assigned via DHCP server.
Function:
Configure the IP address of the
option. Read-only if EN-00 IP Address
Assignment set to DHCP or BOOTP.
Function:
Configure the IP subnet mask of the
option. Read-only if EN-00 IP Address
Assignment set to DHCP or BOOTP.
Function:
Configure the IP default gateway of
the option. Read-only if EN-00 IP
Address Assignment set to DHCP or
BOOTP.
Function:
Read only. Displays the IP address
of the found DHCP or BOOTP
server.
Function:
Function:
Can be automatically assigned when
using DHCP.
AF-650 GP Programming Guide
EN-07 Domain Name
Range:
0
[0 - 2147483647] Domain name of the attached network.
EN-08 Host Name
Range:
Blank
EN-09 Physical Address
Range:
0
[0 - 0] Read only. Displays the Physical (MAC) address of
*
EN-1# Ethernet Link parameters
Option:
[0]
Port 1
[1]
Port 2
EN-10 Link Status
Option:
[0]
No Link
*
[1]
Link
EN-11 Link Duration
Range:
0
[0 - 0] Read only. Displays the duration of the present link
*
EN-12 Auto Negotiation
Option: Function:
[0] Off Link Speed and Link Duplex can be configured in
[1] On
EN-13 Link Speed
Option:
[0]
None
*
[1]
10 Mbps
[2]
100 Mbps
DET-618C
Function:
Can be automatically assigned when using
DHCP network.
Function:
[0-19 characters]
Logical (given) name of option.
Function:
the option.
Function:
Applies for whole parameter group.
Index [0] goes for Port 1.
Index [1] goes for Port 2.
Function:
Read only. Displays the link status of the Ethernet
ports.
Function:
on each port in dd:hh:mm:ss.
Configures Auto Negotiation of Ethernet link
parameters, for each port: ON or OFF.
EN-13 Link Speed and EN-14 Link Duplex.
Function:
Forces the link speed for each port in 10 or 100
Mbps. If EN-12 Auto Negotiation is set to: [ON],
this parameter is read only and displays the
actual link speed. "None" is displayed if no link
is present.