GE AF-650 GP Programming Manual page 166

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Troubleshooting
Bit
Hex
Dec
7
00000080
128
8
00000100
256
9
00000200
512
10
00000400
1024
11
00000800
2048
12
00001000
4096
13
00002000
8192
14
00004000
16384
15
00008000
32768
16
00010000
65536
17
00020000
131072
18
00040000
262144
19
00080000
524288
20
00100000
1048576
21
00200000
2097152
22
00400000
4194304
23
00800000
8388608
24
01000000
16777216
25
02000000
33554432
26
04000000
67108864
27
08000000
134217728
28
10000000
268435456
29
20000000
536870912
30
40000000
1073741824
31
80000000
2147483648
Table 5.3 Description of Alarm Word, Warning Word and Extended Status Word
The alarm words, warning words and extended status
words can be read out via serial bus or optional network
for diagnostics. See also DR-94 Ext. Status Word.
AF-650 GP Programming Guide
Alarm Word
Alarm Word 2
Motor Th Over
reserved
(A11)
Motor Electronic
reserved
OL Over (A10)
Drive Overld. (A9) reserved
DC under Volt
reserved
(A8)
DC over Volt (A7) reserved
Short Circuit
reserved
(A16)
Inrush Fault (A33) reserved
Mains ph. Loss
reserved
(A4)
Auto Tune Not
reserved
OK
Live Zero Error
reserved
(A2)
Internal Fault
KTY error
(A38)
Brake Overload
Fans error
(A26)
U phase Loss
reserved
(A30)
V phase Loss
reserved
(A31)
W phase Loss
reserved
(A32)
Network Fault
reserved
(A34)
24 V Supply Low
reserved
(A47)
Mains Failure
reserved
(A36)
1.8V Supply Low
reserved
(A48)
Brake Resistor
reserved
(A25)
Brake IGBT (A27)
reserved
Option Change
reserved
(A67)
Drive Restored to
Feedback Fault
factory
(A61, A90)
settings(A80)
Safe Stop (A68)
Safe Stop (A71)
Mech. brake low
Dangerous
(A63)
Failure (A72)
DET-618C
Warning Word
Warning
Word 2
Motor Th Over (W11)
reserved
Motor Electronic OL
reserved
Over (W10)
Drive Overld (W9)
reserved
DC under Volt (W8)
DC over Volt (W7)
DC Voltage Low (W6)
reserved
DC Voltage High (W5)
Mains ph. Loss (W4)
No Motor (W3)
Live Zero Error (W2)
10V Low (W1)
KTY Warn
Brake Overload (W26)
Fans Warn Password Protection
Brake Resistor (W25)
reserved
Brake IGBT (W27)
reserved
Speed Limit (W49)
reserved
Network Fault (W34)
reserved
24V Supply Low (W47)
reserved
Mains Failure (W36)
reserved
Current Limit (W59)
reserved
Low Temp (W66)
reserved
Voltage Limit (W64)
reserved
Encoder loss (W90)
reserved
Feedback Fault (W61,
W90)
Safe Stop (W68)
Safe Stop
(W71)
Extended Status Word
Extended
Status Word
Output Current
High
Output Current Low
Output Freq High
Output Freq Low
Brake Check OK
Braking Max
5
Braking
Out of Speed Range
OVC Active
AC Brake
Password Timelock
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused