GE AF-650 GP Programming Manual page 95

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions
DN-11 Process Data Config Write
Select the process write data for I/O Assembly Instances 101/151.
Elements [2] and [3] of this array can be selected. Elements [0]
and [1] of the array are fixed.
Option:
3
3
[110]
[111]
[190]
[193]
[195]
[197]
[222]
[223]
[653]
[663]
[748]
[890]
[891]
[1280]
[1282]
Select the process write data for I/O Assembly Instances
101/151. Elements [2] and [3] of this array can be selected.
Elements [0] and [1] of the array are fixed.
DN-12 Process Data Config Read
Select the process read data for I/O Assembly Instances 101/151.
Elements [2] and [3] of this array can be selected. Elements [0]
and [1] of the array are fixed.
Option:
[0]
*
[515]
[1200]
[1201]
[1202]
[1203]
[1205]
[1209]
[1210]
[1211]
[1212]
[1213]
[1214]
[1215]
[1216]
[1217]
[1218]
[1219]
[1220]
[1221]
[1222]
[1225]
[1230]
[1232]
94
AF-650 GP Programming Guide
Accel Time 2
Decel Time 2
Digital & Relay Bus Control
Pulse Out #27 Bus Control
Pulse Out #29 Bus Control
Pulse Out #X30/6 Bus Control
Jog Accel/Decel Time
Quick Stop Decel Time
Terminal 42 Output Bus
Control
Terminal X30/8 Bus Control
PCD Feed Forward
Bus Jog 1 Speed
Bus Jog 2 Speed
Fieldbus CTW 1
Fieldbus REF 1
None
Readout: actual setup
Control Word
Reference [Unit]
Reference %
Status Word
Main Actual Value [%]
Custom Readout
Power [kW]
Power [hp]
Motor Voltage
Frequency
Motor current
Frequency [%]
Torque [Nm]
Speed [RPM]
Motor Thermal
KTY sensor temperature
Motor Angle
Torque [%] High Res.
Torque [%]
Torque [Nm] High
DC Link Voltage
Brake Energy /s
DN-12 Process Data Config Read
Select the process read data for I/O Assembly Instances 101/151.
Elements [2] and [3] of this array can be selected. Elements [0]
and [1] of the array are fixed.
Function:
Option:
[1233]
[1234]
[1235]
[1238]
[1239]
[1248]
[1250]
[1251]
[1252]
[1253]
[1257]
[1260]
[1261]
[1262]
[1263]
[1264]
[1265]
[1266]
[1267]
[1268]
[1269]
[1270]
[1271]
[1272]
Function:
[1273]
[1274]
[1275]
[1276]
[1277]
[1284]
[1285]
[1287]
[1290]
[1291]
[1292]
[1293]
[1294]
[1500]
[1501]
[1502]
DET-618C
Brake Energy /2 min
Heatsink Temp.
Drive Thermal
Logic Controller State
Control Card Temp.
Speed Ref. After Ramp [RPM]
External Reference
Pulse Reference
Feedback[Unit]
Digi Pot Reference
Feedback [RPM]
Digital Input
Terminal 53 Switch Setting
Analog Input 53
Terminal 54 Switch Setting
Analog Input 54
Analog Output 42 [mA]
Digital Output [bin]
Freq. Input #29 [Hz]
Freq. Input #33 [Hz]
Pulse Output #27 [Hz]
Pulse Output #29 [Hz]
Relay Output [bin]
Counter A
Counter B
Prec. Stop Counter
Analog In X30/11
Analog In X30/12
Analog Out X30/8 [mA]
Comm. Option STW
Drive Port CTW 1
Bus Readout Alarm/Warning
Alarm Word
Alarm Word 2
Warning Word
Warning Word 2
Ext. Status Word
Operating hours
Running Hours
kWh Counter
Function:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents