Honeywell Notifier ID50 Installation, Commissioning & Configuration Manual page 72

Hide thumbs Also See for Notifier ID50:
Table of Contents

Advertisement

ID50 Series Panel - Installation, Commissioning & Configuration Manual
or
1
CAUTION:
This product is not compliant
EN
EN
12094-1
12094-1
with EN 12094-1.
!
!
Fire extinguishing installations in
Europe are required to be certified as
compliant to this standard.
Extinguishing System Outputs
ESE
Extinguishing System Trigger
(not monitored /not disabled by
FWP4)
EST
Extinguishing System Trigger
(not monitored)
ESO
Extinguishing System Output
(monitored)
RLE
Relay Output Module (not
monitored /disabled by FWP4)
CTE
Control
Output
(monitored for open and short
circuits /disabled by FWP4)
997-263-000-11, Issue 11
January 2010
If no device is found at the selected address, the LCD
2
[Sensor]
[Module]
A specific address can only be configured if:
a. A device has previously been auto-learnt at the
b. The off-line tool was used to configure the device type
Sensors
The following sensor configuration settings are selectable:
a. The assigned zone (see Section 5.6.1.1, Zone Setting),
b. The sensor sensitivity (see Section 5.6.1.2, Sensor
c. The device text string (see Section 5.8, Zone Texts).
[Sensor nn - AAA] 1 : Zone (nn)
3 : Sensitivity
Input Modules
The following input module configuration settings are selectable:
a. The assigned zone (see Section 5.6.1.1, Zone Setting),
b. The type of input device (MCP, DKM, MON, ZMX, MNS,
Note: The AUX device type CANNOT be changed.
c. The device text string (see Section 5.8, Text Editing).
[Module nn - AAA] 1 : Zone (nn)
3 : CBE Rule (nn) 4 : [
Output Modules
The following output module configuration settings are
selectable:
a. The assigned zone (see Section 5.6.1.1, Zone Setting),
b. The type of output device (SDR, SDH
1
2
Module
c. The CBE Rule number. It is NOT possible to change
68
displays one of the messages below:
Snn (xxx) No device learnt
Mnn (xxx) No device learnt
address, or
present.
Sensitivity Setting), and
4 : [
Blank/Existing Text
MRL, IRL; Extinguishing System inputs: AUX - Hold Switch
and Abort Switch (see Section 5.6.1.3, Type Setting),
Blank/Existing Text
EST
, ESO
, ESM, TxD, ESE
2
2
Section 5.6.1.3, Type Setting).
Sounders enabled with high-load monitoring function.
These output device types are subject to extinguishing
system disablement if the option to automatically disable
transmission and extinguishing system devices is
configured (refer to Section 5.5.3.14 TD/ES Disablement
at Access Level 2).
the configuration of the associated CBE Rule.
]
2 : Type
]
, CTL, RLY,
1
, RLE
and CTE
) (see
2
2
2