Signalling Line Circuit (Slc) - Learn - Honeywell Notifier ID50 Installation, Commissioning & Configuration Manual

Hide thumbs Also See for Notifier ID50:
Table of Contents

Advertisement

ID50 Series Panel - Installation, Commissioning & Configuration Manual
4
2
or
1
5
OPAL devices are programmed
(initialised) by the panel as part
of a learn operation. Therefore,
when auto-configuring OPAL
devices, there is a short delay
before the progress bar is displayed.
The (S)ensor is replaced
with (M)odule when
learning modules and the
device types change
appropriately.
Optiplex (OPX/SM2), SMART 3 and
SMART 4 (ID60 only)
sensors are learnt as type
MLT. Manually change to
type OPX/SM2, SM3 or
SM4, respectively.
997-263-000-11, Issue 11
January 2010
[Blank/Existing Text
> : Next
Note: For further information on changing text, refer to

5.6.2 Signalling Line Circuit (SLC) - Learn

This option provides automatic recognition of the devices
connected to the SLC loop. The panel searches and learns
all the devices on the loop. The panel prompts for selection
of the loop polling protocol, CLIP only or to Enable OPAL
protocol, before starting a learn operation. To perform the
Learn procedure:
[S1 SLC]
1 Using the numeric keypad, press the '
2
[S1 LEARN]
2 : Enable OPAL protocol
2 Select the appropriate loop polling option. Using the
[SLC]
3 The LCD prompts for confirmation. Press the '
4 One of the following is then displayed on the LCD. Press
a. If learning sensors or modules that have been added
[LEARN]
: Accept
b. If learning any removed sensors or modules, the LCD
[LEARN]
: Accept
c. If Learning a new loop or there is no change on the
[Learn] Learn in progress
76
]
: Char
< : Previous
u1:Delete
Section 5.8, Zone Texts.
1 : Devices
2 : Learn
select the Learn option.
1 : All CLIP protocol
numeric keypad press either the '
Learn Devices?
key to start the Learn process.
the '
' to Accept (confirm) a single device, '
5
(ignore) the device and move to the next changed device
or using the numeric keypad press '
(confirm) changed devices. Press the '
and return to the learn devices prompt.
to the loop, the LCD displays the first new device.
New device added : Snn
> : Skip
8 : Accept all
displays the first removed device.
Device removed : Snn
> : Skip
8 : Accept all
loop, the LCD displays a progress bar.
: Done
u3:Insert
' button to
2
: More
' or the '
' button.
1
2
'
5
' to Skip
6
' to Accept all
8
' to Cancel
4
ION
< : Cancel
ION
< : Cancel

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Notifier id60

Table of Contents