Comtech EF Data LPOD PS-1 Installation And Operation Manual page 58

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C-/Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Remote Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Temperature
N/A
*Retrieve next 5
N/A
unread Stored
Alarms
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric codes: i.e.,
Response to
ASCII codes between 48 and 57)
Query
4 bytes
Query only..
Returns the temperatures of the Heatsink in the form
of a sign byte followed by 3 bytes for the temperature.
TMP=+26.0
145 bytes
Query only.
The unit returns the five oldest stored events in the
alarm log, and if there are no events in the log the unit
will reply with LNA*. All events that are read from the
log are also automatically removed from the log.
Reply format:
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr''lf'
Where:
YYYYYYYYYY is the fault description.
ZZ is one of the event types listed below:
FT = Fault
OK = Clear
IF = Information
The rest of the string is a date / time stamp.
Example: <1/LNA?'cr'
>0001/LNA='cr'
LOG CLR IF 175503 052307'cr'
FAN #1 FT 175504 052307'cr'
OVR TMP FT 175504 052307'cr'
FAN #1 OK 175504 052307'cr'
IIC BUS FT 175504 052307'cr''lf'
Response to
(Target to controller)
3–24
Query
(Instruction
Command
Code and
qualifier)
N/A
TMP?
N/A
LNA?
Revision 0
MN-LPOD
Response to
query
(Target to
controller)
TMP=sxxx
(See description
for details of
arguments)
LNA=YY..ss
(See description
for details of
arguments)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LPOD PS-1 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Lpod ps-2

Table of Contents