LPOD C-/Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Remote Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Remote Baud
SBR=
Rate
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric codes: i.e.,
Response to
ASCII codes between 48 and 57)
Query
4 bytes
Command or Query.
Set remote baud rate as follows:
2400 = 2400 baud
4800 = 4800 baud
9600 = 9600 baud
19K2 = 19200 baud
38K4 = 38400 baud
Example: <1/SBR=9600'cr'
>0001/SBR=9600'cr''lf'
Note: When changing baud rates remotely the
response to the command will be returned using the
same baud rate as that used to send the command.
Default Value: 9600
Response to
(Target to controller)
SBR= (message ok)
SBR? (received ok, but
invalid arguments
found)
3–19
Query
(Instruction
Command
Code and
qualifier)
SBR?
Revision 0
MN-LPOD
Response to
query
(Target to
controller)
SBR=xxxx
(Same format as
command
arguments)