Comtech EF Data LPOD PS-1 Installation And Operation Manual page 48

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C-/Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Remote Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Low forward
LPT=
Power Threshold
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric codes: i.e.,
Response to
ASCII codes between 48 and 57)
Query
5 bytes
Command or Query.
This command allows the user to set the threshold for
the low forward power alarm/fault. If the forward power
drops below the specified value, the alarm/fault will be
indicated. Setting this parameter to 000.0 effectively
disables the threshold
Example: <1/LPT=000.0'cr'
>0001LPT='cr''lf'
Default Value: 000.0
Response to
(Target to controller)
LPT = (message ok)
LPT? (received ok, but
invalid arguments
found)
LPT * (message ok, but
not permitted in current
mode)
3–14
Query
(Instruction
Command
Code and
qualifier)
LPT?
Revision 0
MN-LPOD
Response to
query
(Target to
controller)
LPT =xxx.x
(Same format as
command
arguments)