Comtech EF Data LPOD PS-1 Installation And Operation Manual page 49

C-/ku-band outdoor amplifier/block up converter (buc)
Table of Contents

Advertisement

LPOD C-/Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Remote Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Concise
N/A
Maintenance
Status
Concise RF
N/A
Power FET
Current Status
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric codes: i.e.,
Response to
ASCII codes between 48 and 57)
Query
95 bytes
Query only.
Used to Query the Maintenance status of the unit in a
concise format. The response is semicolon delimited.
This is the concise version of the RMS command.
Example:
<1/CMS?
>0001/CMS=aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;
ggg.g;hh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;
nnn.n;ooo.o;ppp.p;qqq.q;'cr''lf'
Where:
aaa.a = P24V1
bbb.b = P24V2
*ccc.c = LNBVT
ddd.d = P13VT
eee.e = A10V1
*fff.f = A10V2
ggg.g = P7V8T
hhh.h = P5V8T
iii.i = P2V5T
jjj.j = P1V2T
kkk.k = N5V8T
*lll.l = FANR1
*mmm.m = FANR2
*nnn.n = BUCVT
ooo.o = FWPWR
*ppp.p = REFVT
*qqq.q = LNBCS
rrr.r = ATEMP
*Note: ccc.c, fff.f, lll.l, mmm.m, nnn.n, and ppp.p, and
qqq.q will appear if the appropriate model/options have
been selected/installed.
Variable length
Query only
depending on the
Concise version of RFS.
number of FETs
Example: CFS=xxx,xxx,x.x,x.x,..........,x.x,
installed in the
amplifier
Response to
(Target to controller)
3–15
Query
(Instruction
Command
Code and
qualifier)
N/A
CMS?
N/A
CFS?
Revision 0
MN-LPOD
Response to
query
(Target to
controller)
CMS=x....x
(See description
for details of
arguments)
CFS=x.....x
(See description
of RFS. Note that
each argument is
separated by a
comma.)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LPOD PS-1 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Lpod ps-2

Table of Contents