LPOD C-/Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Remote Commands
Command
(Instruction
Parameter Type
Code and
Qualifier)
Enable Statistics
ESL=
Logging
Phase 2 Release
Set Statistics
SSI=
Interval
Phase 2 Release
Enable Statistics
ESA=
Averaging
Phase 2 Release
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric codes: i.e.,
Response to
ASCII codes between 48 and 57)
Query
1 byte
Command or Query.
Enables or Disables the statistics logging function.
0 = Disable
1 = Enable
Example: <1/ESL=1'cr'
>0001/ESL='cr''lf'
Default Value: 0
2 bytes
Command or Query.
Sets the interval at which statistics are logged.
Minimum resolution is 1 minute, maximum is 99
minutes.
Example: <1/SSI=90'cr'
>0001/SSI='cr''lf'
Default Value: 90
1 byte
Command or Query.
Enables or Disables averaging of statistics data at a
rate of once per second for 10 second. If Disabled,
burst values will be logged instead of averaged values.
0 = Disable
1 = Enable
Example: <1/ESA=0'cr'
>0001/ESA='cr''lf'
Default Value: 0
Response to
(Target to controller)
ESL= (message ok)
ESL? (received ok, but
invalid arguments
found)
SSI= (message ok)
SSI? (received ok, but
invalid arguments
found)
ESA= (message ok)
ESA? (received ok, but
invalid arguments
found)
3–33
Query
(Instruction
Command
Code and
qualifier)
ESL?
SSI?
ESA?
Revision 0
MN-LPOD
Response to
query
(Target to
controller)
ESL=x
(Same format as
command
arguments)
SSI=xx
(Same format as
command
arguments)
ESA=x
(Same format as
command
arguments)