Priming

Priming the freezer removes all excess
air and sanitizer from the freezing cylinder
and sets the proper overrun for the first
cylinder of product. Always have clean,
sanitized hands when handling mix feed
assemblies. Handle only the top 1". Make
sure the mix feet tube assembly and the
inside of the hopper cover are cleaned
with sanitizer.
1. Wash and sanitize your hands and
forearms.
2. Place an empty container under the
dispense head. Install the mix feed
tube assembly in the closed position,
as shown in figure 8-2, into the mix
feed drain in the hopper. Pour a
minimum of 2-1/2 gallons of mix into
the hopper.
3. Hold the plunger open and remove
the mix feed tube to allow mix to push
out the sanitizer. When pure mix
flows from the dispense head close
the plunger.
4. When the mix stops bubbling install
the mix feed tube into the mix feed
hopper drain in the "open" position.
Place the selector switch to the
"AUTO" position.
24
Pin is in line with hole.
Look through top hole
in tube — you should
see clear through.
Figure 8-2
Mix Feed Tube Positions
Failure to completely remove sanitizer
or water from the freezing cylinder
before placing in "AUTO" will damage
the freezer.
5. Fill the hopper with mix and Install the
hopper cover.
6. During long idle periods, the regulator
should be closed — but remember —
when dispensing product, ensure
that the mix feed regulator is
"OPEN" at all times. If not open,
the flow of mix will be restricted. If
lubricant blocks the inlet hole in the
tube it would also restrict the flow of
mix.
Pin is not in line with hole.
CLOSED
Look through top hole in
tube — you should see the
inner white plastic insert
tube (regulator) blocking the
opening.
Important: