7
Assembly
6. See figure 7-4 and o-ring chart in
the replacement parts section of this
manual. Install the head o-ring (2) into
the groove on the back of the dispense
head (5),
7. (Install the o-rings (17, 18) on the
plunger (14). Lubricate the o-rings.
8. Install the o-rings (12) onto the pivot
post (13). Lubricate o-rings lightly. Insert
pivot post into the head so the holes are
toward the back.
9. Install the mixer shaft bushing (15) into
the plunger (14).
10. Install the plunger (14) into the head
(5) just past the top o-ring with the slot
facing back. Turn slot slightly to the left
and hook handle (11) into the slot. With
handle in the slot turn the slot to the
back.
11. Place the keeper (4) through the handle
(11), pivot post (13) and head (5) until it
locks in place.
12. Lubricate the inside surface of the
beater bearing bushing (3) and place
in the head (5) making sure to align
bushing key into head slot, as shown in
figure 7-5.
Match the key on the bushing. Make
sure the key aligns with the slot. Failure
to install the bushing properly in the
dispensing head will damage the head.
Figure 7-5 Head Bushing
184592-01
ELECTRO FREEZE Shake Model CS705-M2
— continued
Important:
13. Install the dispensing head onto the
freezer by tilting the top of the head
towards you, aligning the studs with the
holes in the head, and sliding toward
the freezer. As you push the head
towards the freezer, carefully rock it
into place.
14. Tighten the hand knobs simultaneously,
finger-tight only.
Important:
Excessive force will damage the head.
Do not use tools to tighten.
15. Insert mixing shaft (8) into the bottom
of the head (5) with mixer paddle
towards the bottom. Pull back the
sleeve on the end of the flexible
spinner tube in the switch box and
insert mixing shaft into tube, turning
until it snaps into place.
16. Install the o-ring (10) by pushing it
into groove in the mixing chamber (9).
Lightly lubricate the o-ring. Install the
mix chamber on to the bottom of the
head by placing over bolts and turn to
lock in place.
17. Install the actuator rod (16) by placing
one end into hole in the bottom of the
switch box and the other end in the
indent in the plunger behind the flex
shaft.
18. Place flex shaft cover (1) on top of
head using bolts to lock in place.
Important:
The freezer will not dispense product
without the flex shaft cover in
place.
19. Install the five o-rings (7) on quick
connect fittings (6) on the mix chamber.
Lightly lubricate o-rings..
20. Push each syrup line quick connect (6)
onto fitting of the mixing chamber (10).
—continued