8.2 Priming - ELECTRO FREEZE FREEDOM 360 Series Operator's Manual

Soft serve twist freezer
Hide thumbs Also See for FREEDOM 360 Series:
Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Model 99T-RMT

8.2 Priming

Priming the freezer removes all excess air from the freezing cylinder and set s the
proper overrun for the first cylinder of product.
and forearms with an approved sanitizer.
only, insert the pickup tubes into the
sanitized mix tanks through the small
hole in the rear covers and set tanks in
the cabinet.
install the front covers.
through the large hole in the rear cover,
and connect the probe cords to the
probes and to the back of the cabinet.
and close the cabinet door.
the dispensing head on the drip tray.
plugs.
and allow the mix to push the remaining
sanitizer from the tubing and freezer
cylinder.
Figure 8-1
30
1. Wash and sanitize your hands
2. Holding the top 6-inch portion
3. Fill the mix tanks with mix and
4. Insert the sanitized mix probes
5. Turn the cabinet switch to "ON"
6. Place an empty container under
7. Open the plungers and air bleed
8. Turn the MTS switches to "ON"
9. Close the plungers when pure
mix is being expelled.
Important:
Failure to completely remove sani-
tizer or water from the freezing cylin-
der before placing in "AUTO" will
damage the freezer.
10. When mix is coming out of the
air bleed plug openings in the bottom of
the head, close the air bleed plugs. Wait
for the MTS to fill the cylinders and shut
off.
11. After the cylinders are pressur-
ized and the MTS has cycled off (ap-
proximately 30 seconds) turn both DAY/
NIGHT switches to "DAY" and both
SELECTOR switches to "AUTO."
12. Allow the freezer to cycle for 15
minutes. Sanitize the nozzles and install
on the head. The product is now ready
to serve.