ELECTRO FREEZE COMPACT Series Operator's Manual page 38

Shake freezer
Hide thumbs Also See for COMPACT Series:
Table of Contents

Advertisement

ELECTRO FREEZE Shake Model CS705-M2
9.2
Draining Product from Freezer
NOTE: It is your responsibility to be
aware of and conform to the requirements
for meeting local, state, and federal laws
concerning the frequency of cleaning and
sanitizing the freezer.
To remove frozen product from the
cylinder, perform the following steps:
1. Remove the flex shaft cover.
2. Place the selector switch in the
"CLEAN" position.
3. Place a clean, sanitized container
under the dispensing nozzle on the
drip tray.
4. Remove the mix feed tube from the
hopper. (See figure 9-3).
5. Disconnect the syrup lines.
6. Twist and pull down the mixing
chamber removing it from the head.
7. Disconnect the mixer shaft by
releasing the coupling while pulling on
the bottom.
8. Take parts to sink.
9. Place a clean, sanitized container
under the dispensing nozzle on the
drip tray. Dispense the product until
the mix is removed. Place the selector
and syrup switches to "OFF" and
continue dispensing product until it
quits flowing. Close the plunger. If local
health codes permit, cover the rerun
product container and place it in the
cooler. (See 10.2 General Information -
Rerun).
10. Pour 2 gallons of cold water into the
hopper. Place the selector switch to
"CLEAN" and dispense the cold water.
DO NOT use hot water. Damage to the
freezer could occur.
28
CAUTION
To avoid contact with moving
parts, deactivate spinner by
removing flex shaft cover.
Spinner will not operate with
cover removed.
Important:
11. Follow with 2 gallons of warm water
and repeat until the freezer dispenses
clear water. With most of the water
dispensed, place selector switch in the
"OFF" position and drain off remaining
water.
12. Prepare 2 gallons (7.6 liters) of
sanitizing solution in a container.
Sanitizing solution must be mixed
according to manufacturer's
instructions to yield 100 ppm available
chlorine solution (example: Stera-
Sheen Green Label).
13. Pour all the sanitizing solution into the
hopper pan. Using a clean brush scrub
the hopper walls.
14. Place the selector switch to the
"CLEAN" position and allow the beater
to run for 5 minutes.
15. Place an empty container under the
dispensing head. Drain the sanitizing
solution from the cylinder by slowly
pulling down on the dispense handle.
Open and close the handle several
times while draining.
16. With most of the sanitizing solution
drained, Place the selector switch to
the "OFF" position and drain remaining
solution from the freezer and close the
plunger.
17. Proceed to sections 6 DISASSEMBLY
AND CLEANING, 7 ASSEMBLY AND
8 STARTUP INSTRUCTIONS.
TUBE-MIX FEED
Tube-Mix Feed
O-Ring
O-RING
Figure 9-3
O-RING
O-Ring
INSERT - ASSY.
Insert-Assy. Mix
MIX FEED
Feed
184592-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs705-m2

Table of Contents