*ATC BLOWER MOTOR INOPERATIVE —
TEST
8
Turn the ignition off.
Disconnect the Body Control Module C2 harness connector.
Ensure the Blower Motor and Blower Motor Power Module are connected at this
time.
Turn the ignition on and observe the Blower Motor.
Is the Blower Motor running at full speed?
Yes → Replace the Body Control Module.
→ Go To 9
No
9
Turn the ignition off.
Disconnect the Blower Motor Power Module harness connector.
Disconnect the Blower Motor 2-way harness connector at the Blower Motor Power
Module.
Connect a jumper wire between the Fused Ignition Switch Output circuit in the
Blower Motor Power Module connector and the DG wire in the Blower Motor
connector.
Connect a jumper wire between the Ground circuit in the Blower Motor Power
Module connector and the Black wire in the Blower Motor connector.
Turn the ignition on.
Listen to the blower motor for proper operation.
Did the Blower Motor operate at full speed?
Yes → Replace the Blower Motor Power Module.
→ Replace the Blower Motor.
No
ACTION
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.