Roland R1000 Series Manual page 87

Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0063191 / 1.3
System parameter 8: Deleting all program parameters (measuring programs).
system parameter:
clear prog. param.
Fig. 72: Deleting of all program parameters
Selectable options:
yes
no
System parameter 9: Switching the password function on / off.
system parameter:
password active
Fig. 73: Switching the password on / off
Selectable options:
yes
no
System parameter 10: Assigning a password.
system parameter: 10
set password L20
0000
Fig. 74: Assigning a password
To change the password, press the ENTER key. The first digit flashes. Set the desired digits by
pressing the ▲ ▼ keys.
Press ENTER to move to the next digit. After setting the last digit, press ENTER and the password
is stored.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
8
no
Attention
The deletion cannot be undone.
9
no
Attention
If password protection is not activated, then all parameters can be
accessed at any time. This is recommended only during starting-up
the system. For daily operation the password function should be
activated.
Manual
Start-up
87