Adjustment Parameters - Roland R1000 Series Manual

Double sheet control system with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0063191 / 1.3
7.8

Adjustment parameters

Adjustment parameters are parameters, which are only valid for this individual system; they cannot
be transferred to other systems.
Adjustment parameter 1: Measuring channel calibration
This is required before operating a new system, to replace a sensor or a control unit. Start by
placing a calibration sheet between the sensors. The thickness of the calibration sheet is stored in
the unit.
Depending on the sensor type, following sensor distances are allowed:
LAAS10 / LAAS10+:
LAAS40 / LAAS40+:
LAAS200 /LAAS200+:
The measuring channel calibration is valid to all programs.
adjust parameter: 1
measuring channel
calibration
ok
Fig. 44: Selection of measuring channel
Display:
missing:
ok:
To perform measuring channel calibration press the ENTER key.
Following possibilities can be selected:
no:
yes:
measuring channel: (1 / 2 / 3 / 1+2 / 1+3 / 2+3 / 1+2+3):
L20-XX-S
adjust parameter: 1
thickness of
calibration sheet
0.500mm
Fig. 45: Enter the thickness of calibration sheet
Enter the thickness of the calibration sheet at measuring channel calibration.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
10 mm
40 mm
200 mm
Note
LAAS10 / LAAS10+ and LAAS200 /LAAS200+ are in preparation.
Measuring channel calibration at one measuring channel has not
been performed yet.
Measuring channel calibration at one measuring channel has been
performed.
Do not perform measuring channel calibration.
Perform (again) measuring channel calibration at selected channels.
(for L20-XX-S).
Perform (again) measuring channel calibration at selected channels.
(for L20-3-XX-S and depending on selected sensors).
L20-3-XX-S
adjust parameter: 1
0.500mm ENTER start
Manual
±
1 mm
±
2.5 mm
±
10 mm
thickness of
calibration sheet
Start-up
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

L20