Start-up
L20-XX-S
adjust parameter: 1
feed calibration
sheet at channel
push ENTER
Fig. 46: Feed the calibration sheet
L20-XX-S: At this point place the calibration sheet in the measuring station. The calibration is
performed punctual. During the calibration a sheet must be between the sensors.
L20-3-XX-S: Now the calibration sheet is placed in the measuring station or passed through the
measuring station. Confirm by pressing the ENTER key.
Now the rated sensor range is shown. The margin areas must be avoided.
adjust parameter: 1
rated sensor range
37.5 ... 42.5mm
AB1 active: 41mm
Fig. 47: Showing of the rated sensor range
If several measuring points have been calibrated, the ABs will be listed consecutively in the last
row. The measuring channel calibration is completed by pressing the ENTER key.
Adjustment parameter 2: Controlling the sensor gaps with the calibration sheet.
adjust parameter: 2
control with
calibration sheet
Fig. 48: Select the control with the calibration sheet
To perform a control press the ENTER key.
Selection options:
no:
yes:
measuring channel:
78
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
L20-3-XX-S
adjust parameter: 1
push ENTER to finish
Attention
For L20-3-XX-S dynamic calibration is advantageous because
localized thickness variations or fluctuations in the calibration piece
will have less impact on the calibration.
Note
Occurring fault messages read section „9. Fault messages".
no
Do not perform control.
Perform control (At L20-XX-S)
1 / 2 / 3 / 1+2 / 1+3 / 2+3 / 1+2+3
perform controls at selected measuring channels
(At L20-3-XX-S and depending on connected sensors)
Manual
feed calibration
active
B0063191 / 1.3